Contura C i5 Installation Instructions Manual

Advertisement

Quick Links

Installation instruction

Lighting Instructions

C i5
www.contura.eu

Advertisement

Table of Contents
loading

Summary of Contents for Contura C i5

  • Page 1: Installation Instruction

    Installation instruction • Lighting Instructions • C i5 www.contura.eu...
  • Page 2 See rating plate on the insert Intended area of use Heating of rooms in residential buildings Fuel Wood MANUFACTURER Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden CHECKS According to AVCP System 3 European standard...
  • Page 3 A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new cassette. As a new owner of a Contura cassette, you have secured a product with timeless design and long service life. Contura also has a combustion process that is both environmentally friendly and efficient, for the best heat production.
  • Page 4: Technical Details

    Part 15a B-VG in accordance with test report RRF- 29 12 3029 Norwegian standard, SINTEF - 110-0391 Type approved in SE in accordance with SITAC xxx Dimensions C i5 Alternative flue connections Ext. Ø124 Utv. Ø124 Ext. Ø124 Utv. Ø124 Flue connection –...
  • Page 5: Supply Of Combustion Air

    INSTAllATION Supply of combustion air For optimum function and efficiency a supply air of Ø67 mm. When duct routing further than 1 m the pipe diameter connection(accessory) is recommended via a separate channel. must be increased to 100 mm and a correspondingly larger wall The air can be supplied indirectly via a vent in the outer wall, or vent must be selected.
  • Page 6: Installation

    INSTAllATION Installation The cassette is designed to be installed in existing open hearths. There must be a 20 mm air gap around the cassette for optimum hot air convection. Use the cardboard template and check that there is sufficient space for the installation. Fold out template to see where the sleeve connection ends up.
  • Page 7 INSTAllATION Preparations Remove any old damper sheets and clean To simplify installation a hole can be made in the the stove. stove hood. After installation is completed this can be fitted with a grille and provide additional heating. Removing the internal parts Remove internal loose cast iron components Handle the hearth and fire bricks as follows.
  • Page 8 INSTAllATION...
  • Page 9 INSTAllATION Connection to chimney A flexible hose is recommended for ease of installation (sold as an accessory). Secure the sleeve in the hose. Connect and seal carefully between the hose and the chimney according to the separate instruction. Angle the hose so that the sleeve connector ends up where the template shows the cassette’s connection surface Seal carefully between the hose and the chimney using mineral wool.
  • Page 10 INSTAllATION Alternative connection to chimney The cassette can also be connected with fixed pipe inserted up the chimney Seal carefully between the hose and the chimney using mineral wool and seal any pipe joints using heat–resistant sealant. Connection Ensure that the cassette is stable by adjusting the feet.
  • Page 11 INSTAllATION Hot air grate (accessory) Cover grille (accessory) Chimney connection (accessory)
  • Page 12: Lighting Instructions Lighting In The Right Way

    Lighting in the right way Lighting Contura i5 is intended to produce secondary heating for the accommoda- tion. It is important that the correct amount of wood is used, especially If the house has mechanical ventilation, open a window near to the fire- when lighting.
  • Page 13: Maintenance

    Damage to painted parts, e.g. small scratches, can be rectified with Contura touch-up paint. Contact the dealer. Parts located near the actual seat of the fire may require replacing. Exam- ples of such parts are the hearth surround.
  • Page 14 Abnormal amounts of soot form on the glass There is always a certain amount of soot on the glass and this is added to • Check that the chimney length meets Contura’s recommendation, which with each lighting. Soot on the glass is caused by three things: is at least 3.5 m.
  • Page 16 NIBE AB · Box 134 · SE-285 23 Markaryd · Sweden www.contura.eu Contura reserves the right to change colours, materials, dimensions and models at any time without special notice. 811175 IAV SE-EX Ci5-6 Your dealer can give you the most up to date information.