Summary of Contents for Contura NIBE i50

  • Page 1 Installation instructions Ci50 contura.eu...
  • Page 2 Trade name Contura i50 Intended area of use Heating of rooms in residential buildings Fuel Wood MANUFACTURER Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden VERIFICATION According to AVCP System 3 European standard EN 13229:2001/A2:2004/AC:2007 Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625.
  • Page 3 +46 433 275100 THIS DECLARATION OF CONFORMITY IS ISSUED UNDER OUR SOLE RESPONSIBILITY FOR THE FOLLOWING PRODUCT: Trade name Contura i50-series: i50 / i51 (A/AN/T/S) Identification of product www.contura.eu THE OBJECT OF THE DECLARATION DESCRIBED ABOVE IS IN CONFORMITY WITH -...
  • Page 4: Table Of Contents

    CONTENTS A warm welcome to Contura. Welcome to the Contura family. We hope you will get a great deal of pleasure from your new insert. Congratulations on your purchase of a Contura insert. You have acquired a reliable quality product with a timeless design and long service life.
  • Page 5: Technical Specifications

    This manual contains instructions on how To protect the floor in front of the hearth specifications to install the Contura i50. We recommend from falling embers, a non-combustible the insert be installed by a qualified floor covering must be placed at least 300...
  • Page 6: Important Dimensions

    IMPORTANT DIMENSIONS/PRIOR TO INSTALLATION Important dimensions Ci50 * The insert can be lowered 80 mm (at 16 mm intervals). Prior to installation Opening a side glass panel...
  • Page 7 PRIOR TO INSTALLATION...
  • Page 8 PRIOR TO INSTALLATION 10 mm...
  • Page 9 PRIOR TO INSTALLATION Performance check Check the performance of the insert as follows: Use the adjustable feet to level the insert. Check that the door can be opened and closed. Check that the damper knob can be moved back and forth to the max.
  • Page 10 For installation in the UK and in smoke control areas Mandatory for smoke control areas The Contura i50 and i51, 8 kW woodburning stoves has been recommended as suitable for use in smoke control areas. This when burning wood logs and operated in accordance with these instructions and when fitted with a permanent stop to prevent closure of primary air control beyond the 52 mm²...
  • Page 11 PRIOR TO INSTALLATION Installation of metal ba± e plate...
  • Page 12 PRIOR TO INSTALLATION Removing the hearth cladding...
  • Page 13 OPTION Installing Powerstone Option...
  • Page 14: Installation

    INSTALLATION Installation Make sure that the installation complies with national and regional regulations. The installation must be approved by an authorised inspector. Combustion air supply Supply of combustion must be provided. Combustion air can be drawn directly via a duct from outside, or indirectly via a vent in the outer wall of the room where the stove is placed.
  • Page 15: Chimney

    CHIMNEY/SELF-CLOSING DOOR Chimney The insert is approved for connection to a chimney designed to Note that sharp bends and horizontal lengths in a flue pipe reduce withstand flue gas temperatures of up to 350°C. The external the draft in the chimney. The maximum horizontal length of flue diameter of the connection sleeve is Ø...
  • Page 16: Recessing The Insert

    RECESSING THE INSERT Recessing the insert When recessing the insert, adjacent walls that are not classed When connecting a steel flue, please refer to the particular as fire walls or are considered unsuitable for heat loads must manufacturer's installation instructions. Observe the safety be protected by non-combustible material according to the distance to combustible material required by the steel flue Heat specification below.
  • Page 17: Recess Example

    RECESSING THE INSERT Recess example Unless otherwise stated, these Wall of combustible material are the minimum dimensions. Wall of non-combustible material, made of 100 mm aerated concrete in the recess example. Chimney breast Wall of non-combustible material that is not in contact with combustible material and therefore has no minimum thickness requirement.
  • Page 18 RECESSING THE INSERT Sealing Avtätning Area out 600 cm Area ut 600 cm Area out 600 cm Area ut 600 cm Area in 600 cm Area in 600 cm Area in 600 cm Area in 600 cm Area out 600 cm Area ut 600 cm Area out 600 cm Area ut 600 cm...
  • Page 20 NIBE AB · Box 134 · 285 23 · Markaryd · Sweden contura.eu Contura reserves the right to change dimensions and procedures specified in these instructions without prior 811436 IAV SE-EX Ci50-3 notice. Access the latest version at contura.eu 2022-02-04...