operating. Note: Follow the procedures indicated
on the generator switch panel before starting
generator and while running generator. See Figure
H33.
Figure H33: Remote Generator & Blower Switches
(Representative View - Panels Will Vary by Model)
Be sure to operate the bilge blower for at least
four (4) minutes before starting engine or
generator, or whenever operating the engine(s)
at idle speed. Check the bilge blower output
before each use.
5. Open the generator's seacock valve, labeled
GENERATOR SEAWATER, to allow water flow to
the generator for cooling purposes. The seacock is
typically located in the engine room next to the
generator. See Figure H34.
Generator
Seawater
Seacock
(Open Position)
Figure H34: Generator Seawater Seacock & Strainer
(Representative View - Models and Location May Vary)
Electrical Systems - Section H
LED Light
Generator
Strainer
NOTICE
In order to use the generator, you must first
open the seacock valve (handle parallel to the
flow of valve). Failure to open seacock valve
while running generator will cause generator to
overheat and possible failure. When not using
the generator be sure to close the seacock.
6. Open the fuel valve for the generator located in
the engine compartment (if applicable). See Figure
H35.
Figure H35: Generator Fuel Valve
(Representative View - Models and Location May Vary)
7. Start the generator using the remote gen erator
start switch on the 240V AC cabin panel. See
Figure H36.
Remote
Start Switch
Figure H36: Remote Generator & Blower Switches-"ON"
(Representative View - Panels Will Vary by Model)
Owner's Manual Page 98