Set-Up Mode U1 To U9 - Whirlpool Light programmable oven Service & Installation Manual

Whirlpool light programmable oven with boiler
Table of Contents

Advertisement

Set-up Mode U
In the set-up function, it is possible to set the oven controller to match the mechanical set-up
and the choice of software.
If the set-up has been changed in U1, U4 or U15, the oven will be reset.
U1 Oven model
The setting should be set to 1( by pressing the step key ).
You press the temperature key to select a PassThrough model (two doors).
1= one door (standard) 2= two doors
When you have selected the oven model, confirm by pressing the alarm key if the control lamp
flashes.
After that, the controller initializes.
NOTE: ALL settings and programs are reset.
U2 Oven size
You choose the oven size by pressing the step key: 0-7.0= 6, 1= 8, 2= 10, 3= 12, 4= 16, 5=
20, 6= 2 x 10, 7= 2 x 14.
The oven size you have chosen is shown in the field next to the temperature key.
U3 CombiWash
You activate or deactivate CombiClean by pressing the step key.
0=OFF, 1=ON.
U4 Temperature scale
You choose between Celsius and Fahrenheit as scale of temperature by pressing the step key.
0= Celsius 1= Fahrenheit.
You can "even out" the current temperature by pressing the temperature key.
0=OFF, 1=ON
When you have chosen the temperature scale, confirm by pressing the alarm key if the control
lamp flashes.
After that, the controller initialises.
NOTE: ALL settings and programs are reset.
U5 Not in use
U6 Low-temperature steaming
You activate and deactivate low-temperature steaming by pressing the step key.
0= OFF, steaming only possible at 100°C, 1= ON, steaming only possible between 30°C and
120°C.
U7 Preheating at 300°C
You activate and deactivate preheating by pressing the step key.
0= OFF, 1= ON.
NOTE: Preheating at temperatures above 250°C is only possible for max. 15 minutes.
U8 Setting water level sensor
When you press the temperature key, the water level value starts flashing and can then be set
between 40 and 80 (default 70).
If the conductivity of the water is low, set the water level higher.
U9 Automatic restart
You activate and deactivate automatic restart by pressing the step key.
0= OFF, 1= 10 minutes, 2= 30 minutes, 3= 60 minutes.
This means that if there is a power cut, the program that was interrupted will be reassumed
provided that the power returns within the time set.
U10 Programs
You activate the program mode by pressing the step key.
- 16 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Light programmable oven with boiler

Table of Contents