Center Loop System - Elite CSW-200-UL Series Instruction Manual

Csw-200-ul series high traffic commercial gate operator
Hide thumbs Also See for CSW-200-UL Series:
Table of Contents

Advertisement

Attention:
To connect loop detectors,
refer to page 25 and 26.
Important
Loop Perimeter
10 feet to 13 feet
14 feet to 26 feet
27 feet to 45 feet
46 feet to 100 feet
101 feet and up
The wire is continuously wound in
the loop saw slot for the required
number of turns. One turn shown.
Remove sharp inside corners
by making corner cuts
Caution
28
C E N T E R L O O P S Y S T E M
Allows gate to stay open when vehicles are obstructing gate path.
Center Loop
Even with
Edge of
Open Gate
4'
Number of Turns
5
4
3
2
1
(Refer to table above)
This option is for all vehicles including ones less than 14' long.
Center loop system requires two safety loops.
4'
4'
Typical
Road Surface
Sealant
Loop Wire
(3 Wires Shown,
amount varies.
Refer to table)
Recommended Loop Wire
XLPE 12-18 gauge
USE 12-18 gauge
Use heavier wire gauge for a more
durable loop area
1/8" to 1/4"
Saw Slot
The wire must be twisted together 6 twists per foot from
the end of the loop to the loop detector connection.
Home Run
Home Run
1/8" to 1/4"
Saw Slot
Min 1"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csw-200-ul-dmCsw-200-ul-stCsw-200-ul-1hp

Table of Contents