Safety Loop System; Center Loop System - Elite CSW-200-UL series Instruction Manual

Csw-200-ul series high traffic commercial gate operator
Hide thumbs Also See for CSW-200-UL series:
Table of Contents

Advertisement

Allows gate to stay open when vehicles are obstructing gate path.
Attention:
To connect loop detectors,
Refer to built-In
loop detectors
or
Terminal Input
connections.
4'
Caution:
Suggested for vehicles 14 feet or longer. If a vehicle is shorter,
a center loop system is recommended and should be installed.
Allows gate to stay open when vehicles are obstructing gate path.
Center Loop
Even with
Edge of
Open Gate
Caution:
This option is for all vehicles including ones less than 14' long.
Center loop system requires two safety loops.
4'
4'
4'
Typical
Fill Loop Cuts
with Proper
Sealer
4'
Typical
4'
4'
From Loop
1/4"
Three Wire Layers in Loop Cut
4'
1/4"
4'
1 1/2"
Fill
Loop Cuts
with Proper
Sealer
Three Wire Layers in Loop Cut
Twisted
Wires
Cut
1 1/2"
Twisted
Wires
From Loop
Cut