Elite CSW-200-UL series Instruction Manual

Csw-200-ul series high traffic commercial gate operator
Hide thumbs Also See for CSW-200-UL series:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Elite CSW-200-UL series

  • Page 2: Important Safety Instructions

    Installation Instructions Regarding the Gate Operator A) Install the gate operator only when: 1) The operator is appropriate for the construction and the usage Class of the gate. 2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.2 m) above the ground to prevent a 2 1/4inch (57.15 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.
  • Page 3 Gate – A moving barrier such as a swinging, sliding, raising lowering, rolling, or like, barrier, that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area. Vehicular horizontal slide-gate operator (or system) –...
  • Page 4 The CSW-200 is for Vehicular Gate Use Only! NOT for Use on Any Pedestrian: Gateways, Doorways or Passageways. Owners Must Never Let Pedestrains Cross the Path, Step or Hang on the Gate! Never Mount Any Gate Operating Device Accessible Through the Gate!
  • Page 5 Maximum Gate Weight – 600 lbs. Maximum Gate Weight – 1000 lbs. Be sure to read and follow all Elite and UL instructions before installating and operating any Elite products. Elite Access Systems, Inc. is not responsible for improper installations or failure to comply with local building codes.
  • Page 6 Bell Box Red Head Fastener 3/4" PVC 1/2" x 3 1/2" Above 6" Ground Below 30" Ground Concrete Pad 28" 24" Hinge Center 46" Post 2" 14" 25" 35.5" Long Arm 10" 29.5" Short Arm 28" Concrete Pad 24" Sample Installation...
  • Page 7 Sample Installation is Shown on Previous Page. Hinge Center D minus 10" Long Arm 10" Short Arm Distance Concrete Pad Dimension (A) thru (E) are from the center of one pivot point *Refer to Note to the center of another pivot point. Caution: If the gate is longer than 18 feet, follow Chart A...
  • Page 8 Compact Installation Only! “DO NOT” Use These Measurements for a Standard Installation. 20" Minimum Width Hinge Center 33" 2" 9" 26.5" 23" 25.5" 20" 32" Gate Open Gate Closed Long Arm 10" 22" 4" 36" Short Arm 4" 20" 24" Follow the exact measurements, then cut the standard arm to meet the shorter measurements.
  • Page 9 Incorrect Installation Correct Installation Once the gate arm measurements are calculated: weld the bracket on the gate. Weld the longer arm....then weld the shorter arm. Weld Completely Around the Rectangular Tubes...
  • Page 10 Red handle Tighten the Nut must be in 90° this position Fit Pin in Slot Tighten Handle Pull Pull the short arm away from the gate. slippage should occur. If it does, go back and tighten the nut more. Limit Switches Adjustments Loosen...
  • Page 11 2200 Feet Caution: ELITE ACCESS SYSTEMS, INC. is not responsible for conflicts between the information listed in the above chart and the requirements of your local building codes. The information is for suggested use only. Check your local codes before installation.
  • Page 12 Gate in Closed Position Gate is Given an “Open” Command Before Completing a Normal Close-Cycle Adjust the Clutch with a Wrench Gate Smoothly Reverses Direction Gate in with the Clutch Slipping Opened 1/4 to 3/4 Turn Position (Starting Position) (Finishing Position) Typical Clutch Slippage (1/4 Turn) The adjustment is for a gate that is over 300 pounds and 12 feet long or longer.
  • Page 13 Adjusted by Qualified Service Personnel CENTER SAFETY EXIT Maximum Sensitivity DC-BACKUP SYSTEM ON TIMER MS LINK POWER SENSORS OVERLOAD OPEN LEFT OPEN RIGHT FIRE STRIKE RADIO GATE DEPT. OPEN RECEIVER LOCKED EXIT SAFETY CENTER RESET LOOP LOOP LOOP MOTOR Minimum Sensitivity DO NOT TOUCH ALARM SENSOR The level of sensitivity has to do with the weight of the gate and the condition of installation.
  • Page 14 Master and Slave Boards are Interchangeable Master Omni Board Primary Control for System Use Low Voltage Wires to Connect Gate Operators Together Caution: 115 volts per operator required Master Omni Board TIMER Adjust Time Desired 0 to 60 seconds CENTER SAFETY EXIT Slave Omni Board...
  • Page 15 Use Low Voltage Wires to Connect Gate Operators Together Caution: 115 volts per operator required Master Omni Board Slave Omni Board TIMER CENTER SAFETY EXIT CENTER SAFETY EXIT OPEN LEFT OPEN RIGHT DC-BACKUP DC-BACKUP SYSTEM ON TIMER SYSTEM ON TIMER MS LINK POWER MS LINK...
  • Page 16 CENTER SAFETY EXIT Omni Option Board Elite Part # O-OMNI EXB Q C C O P E N S T O P C L O S E M A G L O C K A L A R M A R M E D...
  • Page 17 OPEN RECEIVER LOCKED EXIT SAFETY CENTER RESET LOOP LOOP LOOP MOTOR Power Omni Option Board Elite Part # O-OMNI EXB Ground 7 – Common 8 – Normally Closed 9 – Normally Open MAGLOCK CENTER SAFETY EXIT Magnetic Lock Ground DC-BACKUP...
  • Page 18 Wire Harness Normally Closed CENTER SAFETY EXIT Common Normally Open DC-BACKUP Connection of a Solenoid or Magnetic Lock can be made SYSTEM ON TIMER MS LINK POWER SENSORS OVERLOAD using the J3 plug and three wires supplied with the unit. OPEN LEFT OPEN RIGHT FIRE...
  • Page 19 OPEN STOP CLOSE MAGLOCK ALARM ARMED M/S LINK Omni Option Board Elite Part # O-OMNI EXB CENTER SAFETY EXIT DC-BACKUP OPEN S T O P C L O S E M A G L O C K A L A R M A R M E D...
  • Page 20 SAFETY CENTER RESET LOOP LOOP LOOP MOTOR Wire-Loop “Center Loop” Wire-Loop “Safety Loop” Elite Loop detectors needed to do Wire-Loop “Exit Loop” this function. Elite Part # A ELD Omni Option Board Needed OPEN STOP CLOSE CENTER SAFETY EXIT DC-BACKUP...
  • Page 21 T E R M I N A L I N P U T C O N N E C T I O N S Output Power MADE IN USA OPEN LEFT OPEN RIGHT Terminal 8 = Ground (-) Terminal 10 = 24 DC (+) FIRE STRIKE RADIO...
  • Page 22 Allows gate to stay open when vehicles are obstructing gate path. Attention: To connect loop detectors, Refer to built-In loop detectors Terminal Input connections. Twisted Wires From Loop 1/4" 1 1/2" Typical Fill Loop Cuts with Proper Sealer Three Wire Layers in Loop Cut Caution: Suggested for vehicles 14 feet or longer.
  • Page 23 Allows gate to automatically open for exiting vehicles. Twisted Wires From Loop 1/4" 1 1/2" Fill Loop Cut with Proper Three Wire Layers Sealer in Loop Cut External Loop Detectors Radio Receiver Access Door - A generous allotment of space is allowed for external loop detectors and radio receiver.
  • Page 24 Unscrew Bolt Special tool required for the “optional” security bolt Lift Off Cover Loosen Red Handle Gate can now be manually moved Grab the Gate to Make Adjustments Tighten the Red Handle, Replace the Cover and Bolt when Finished When the power is turned on again, the gate will readjust itself automatically.
  • Page 25 Disconnect 2 harnesses from OmniControl board. Unscrew 3 nuts to remove board. Twice Consecutively, When one of the following events happens an Alarm will Sound! The gate is too heavy or the arm is installed wrong, Refer to Gate Arm Installation A foreign object is on the gate Gate hinges are too tight or frame while the gate is moving.
  • Page 26 DC-1000 Unit Option A: In case of power failure the gate opens automatically one time and stays open. when power is restored the operator returns to normal condition. Bolt-On Wire Motor Harness Option B: Pulley In case of power failure the gate will not open automatically until activated by a key switch or push button.
  • Page 27 Impossible Gate hits driveway Possible Special arm and hinges are required Swivel Arm Elite Part # Q103 OMRON Retro-Reflective Photocell Wiring CENTER SAFETY EXIT LIGHT ON DARK ON Important: This switch must be in the “LIGHT ON” position for the...
  • Page 28 Elite Part # A OMRON OMRON Retro-Reflective Align with Reflector Photocell Reflector Mount to Wall or Floor 4 Wires go to Gate Operator Conduit Omni Control Board and Electronic Box Terminals Mounted Reflector Photocell Sensor Head Wall Danger Gate Open...
  • Page 29: Gate Will Not Close

    T R O U B L E S H O O T I N G L E D I N F O R M A T I O N Resetting Motor Press firmly to reset thermal breaker on the motor. Reset Motor LED Light is “ON”...
  • Page 30 2.You can stop the alarm by using the stop button. 1.The loop detector needs to be reset. 1.Reset the loop detector (If you use Elite “LOOP LED” 2.The wire loop has been disrupted Plug-in Loop detectors, change the setting 3.The loop detector needs to work in a...
  • Page 31 Q118 Q084 Q063 Q269 Stainless Steel Q268 Q062 Q060 Q059 Q061 Q216 Q215 Q244 UL DM / 1 HP Cover Q213 Q246 NON UL Q247 UL Limit Switch Q044 Assembly Q208 Q210 Q217 Q018 Q055 Q054 Q027 Q521 Q018 Q053 Q051 Q052* Q029*...
  • Page 32 Kludge Assembly Electronic Box Assembly Q060 - ARM RELEASE HANDLE Q402 1/2 HP Q403 1 HP Q061 Q061 - OUTPUT SHAFT CLUDGE (T) Q006 - PC BOARD NUTS (SET) Swivel Arm Q018 - 1/2 HP ELECTRIC MOTOR Q198 - SWIVEL ONLY Q019 - CONTROL BOARD NON UL (NOT SHOWN) Q103 Q256 - SOLID ARM, SWIVEL, AND...
  • Page 33 Remote External “Safety” Loop Detectors Control System Three Push Button Key Switch Card Reader Photo Electric Eye Outdoor Digital Lock Key Station Outdoor Digital Lock Outdoor Intercom Indoor Intercom with Intercom Speaker Speaker...