Safety Loop System - Elite CSW-200-UL Series Instruction Manual

Csw-200-ul series high traffic commercial gate operator
Hide thumbs Also See for CSW-200-UL Series:
Table of Contents

Advertisement

Allows gate to stay open when vehicles are obstructing gate path.
Allows gate to stay open when vehicles are obstructing gate path.
Attention:
To connect loop detectors,
refer to page 25 and 26.
Note:
Safety loops connected in
series must have both
loop perimeters added
together to use table
below.
4'
Important
Loop Perimeter
10 feet to 13 feet
14 feet to 26 feet
27 feet to 45 feet
46 feet to 100 feet
101 feet and up
The wire is continuously wound in
the loop saw slot for the required
number of turns. One turn shown.
(Refer to table above)
Remove sharp inside corners
by making corner cuts
Suggested for vehicles 14 feet or longer. If a vehicle is shorter,
Suggested for vehicles 14 feet or longer. If a vehicle is shorter,
a center loop system is recommended and should be installed.
a center loop system is recommended and should be installed.
Caution
S A F E T Y L O O P S Y S T E M
4'
4'
4'
Typical
Number of Turns
5
4
3
2
1
1/8" to 1/4"
Saw Slot
The wire must be twisted together 6 twists per foot from
the end of the loop to the loop detector connection.
4'
4'
Open End of Gate
Home Run
Road Surface
Sealant
Loop Wire
(3 Wires Shown,
amount varies.
Refer to table)
Recommended Loop Wire
XLPE 12-18 gauge
USE 12-18 gauge
Use heavier wire gauge for a more
durable loop area
Home Run
1/8" to 1/4"
Saw Slot
Min 1"
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csw-200-ul-dmCsw-200-ul-stCsw-200-ul-1hp

Table of Contents