Exit Loop System - Elite CSW-200-UL Series Instruction Manual

Csw-200-ul series high traffic commercial gate operator
Hide thumbs Also See for CSW-200-UL Series:
Table of Contents

Advertisement

Allows gate to automatically open for exiting vehicles.
Attention:
To connect loop detectors,
refer to page 25 and 26.
Open End of Gate
4'
4'
Important
Loop Perimeter
10 feet to 13 feet
14 feet to 26 feet
27 feet to 45 feet
46 feet to 100 feet
101 feet and up
The wire is continuously wound in
the loop saw slot for the required
number of turns. One turn shown.
(Refer to table above)
Remove sharp inside corners
by making corner cuts
E X I T L O O P S Y S T E M
4'
4'
4'
4'
Number of Turns
5
4
3
2
1
1/8" to 1/4"
Saw Slot
The wire must be twisted together 6 twists per foot from
the end of the loop to the loop detector connection.
4'
4'
Home Run
1/8" to 1/4"
Road Surface
Saw Slot
Sealant
Loop Wire
(3 Wires Shown,
amount varies.
Refer to table)
Recommended Loop Wire
XLPE 12-18 gauge
USE 12-18 gauge
Use heavier wire gauge for a more
durable loop area
Home Run
Min 1"
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csw-200-ul-dmCsw-200-ul-stCsw-200-ul-1hp

Table of Contents