Vertical Sidewall Applications & Installation - Majestic DVRTSB Homeowner's Installation And Operating Manual

Bay window rear/top convertible direct vent fireplaces
Table of Contents

Advertisement

Vent Opening for Combustible Wall
9³⁄₈"
(240 mm)
10³⁄₈"
(265 mm)
Opening for Noncombustible Wall
7¹⁄₂"
(190 mm)
Fig. 17 Locate vent opening on wall.
Zero clearance sleeve is only required for
combustible walls.
VO584-100
Vent Opening
Adjustable Zero
2/99 djt
Clearance Sleeve
#8 Screws (2)
Adjustable Zero Clearance Sleeve
ZCS101
Fig. 18 Adjustable zero clearance sleeve.
Zero Clearance Sleeve
3/11/99 djt
STEP 3
Measure the horizontal length requirement for the vent-
ing including a 2" (51 mm) overlap, i.e. from the elbow
to the outside wall face plus 2" (51 mm) (or the distance
required if installing a second 90° elbow. (Fig. 17)
STEP 4
Install the 4" (102 mm) vent to the appliance collar and
secure with three (3) sheetmetal screws. Install the 7"
(175 mm) vent pipe to the appliance collar and secure
with three (3) sheet metal screws. It is not necessary to
seal this connection.
It is critical that there is no downward
slope away from the appliance when con-
necting the vent or elbow.
10003848
Framing Detail
VO584-100
Max. Length 12"
(305mm)
#8 Screws (2)
#8 Screws
(2)
Firestop
ZCS101
DVRTSB Bay Window Fireplace
STEP 5
Guide the vent through the vent hole as you place the
appliance in its installed position. Guide the 4" (102
mm) and 7" (175 mm) collars of the vent termina-
tion into the outer ends of the venting. Do not force
the termination. If the vent pipes do not align with the
temination remove and realign the venting at the ap-
pliance flue collars. Attach the termination to the wall
as outlined in the instruction sheet supplied with the
Vertical Sidewall Applications
Since it is very important the venting system maintain
its balance between the combustion air intake and the
flue gas exhaust, certain limitations as to vent configu-
rations apply and must be strictly adhered to.
The vent graph showing the relationship between verti-
cal and horizontal side wall venting will help to deter-
mine the various dimensions allowable.
Minimum clearance between vent pipes
and combustible materials is one 1"
(25mm) on top, bottom and sides unless
otherwise noted.
When the vent termination exits through foundations
less than 20" (508 mm) below siding outcrop, the vent
pipe must flush up with the siding.
It is always best to locate the fireplace in such a way
that minimizes the number of offsets and horizontal
vent length of vent pipe from the flue collar of the fire-
place to the face of the outer wall.
Horizontal plane means no vertical rise exists on this
portion of the vent assembly.
When installing the appliance as a rear
vent unit the 90° Transition Elbow attached
directly to the rear of the unit is not in-
cluded in the following criteria and calcula-
tions, and unless specifically mentioned
should be ignored when calculating vent-
ing layouts.
Fig. 19 Maximum number of 90· elbows per sidewall.
FP1380
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents