28-5/8" (727 mm)
19-1/2" (495 mm)
Gas inlet
X
Y

Dimensions

Optional Outer Trim or
Surround sold separately
Gas connection

Cavity

Check that masonry step does not interfere with install dimensions or
vent pipe.
If mantel is combustible, see section Clearances for allowable
clearances.
Minimum width of fi replace opening at front: 28" (711 mm)
X = 12" (305 mm) or 12-5/8" (321 mm)—varies with outer trim options
Y = 20" (508 mm)
12" (305 mm)
or 12-5/8" (321 mm)
Varies with
outer trim options
9-3/8" (238 mm)
or 10" (254 mm)
Varies with
outer trim options
Electrical inlet
QUALIFIED
INSTALLER
20"
(508 mm)