Section 8. Twelve (12) Volt Installation - Jandy Pro Series Installation Manual

Watercolors led lights underwater large and small light
Hide thumbs Also See for Pro Series:
Table of Contents

Advertisement

Align arrow of the
lens with the pilot
screw
Figure 9.
Alignment of the lens, Face Ring,
housing and Clamps for WaterColors
lights
7.
Reinstall the Jandy Pro Series Light into niche
fixture.
a. Coil the extra four (4) feet of cord around the
fixture or into the base of the niche and place the
light assembly into the niche.
b. Engage the retainer tab on the bottom of the face
ring, then pivot the top of the fixture inward and
tighten the special pilot screw.
WARning
Use only the special pilot screw provided with this
underwater light. This screw mounts and electrically
grounds the housing securely to the mounting ring
and wet niche. Failure to use the screw provided could
create an electrical hazard, which could result in death
or serious injury to pool or spa users, installers or
others due to electrical shock.
8.
If pool is empty, fill the pool until the underwater
light is completely submerged in water before
operating the light for more than 10 seconds. Turn
on main switch or circuit breaker, as well as the
switch, which specifically operates the underwater
light, to check for proper operation.
WARning
Never operate this underwater light for more than
10 seconds unless it is totally submerged in water.
Without total submersion, the light assembly will get
extremely hot, which may result in serious burns or in
damage to the light. This may result in serious injury
to pool or spa users, installers, or bystanders or in
damage to property.
Jandy
Pro Series, WaterColors LED Lights
®
|
Installation Manual
Thick molded
side of the
gasket must
mate with
the body of
the housing
Figure 10. Cross section of Jandy Pro series
WaterColors lED light
section 8. Twelve (12) Volt
installation
A separate 12-Volt AC Transformer is required on all 12-
Volt Models. For Jandy Pro Series WaterColors Light
use a 150-watt multi-tap 12-volt system per light.
nOTE
For optimum performance Jandy Pro Series
recommends to use one transformer per 12-volt light.
To ensure maximum safety, it is strongly recommended
that a transformer that has been listed or recognized by
a Nationally Recognized Testing Laboratory (NRTL) for
the application be used.