System Description
Heater
Cell
The cell must be installed as the
last piece of equipment in the
circulation plumbing system just
before the pool
Figure 1.
Example of Installation

2.1 Product Specifications

Maximum Operating Pressure: 50 psi
Minimum Flow Rate: 40 gpm
Maximum Flow Rate: 92 gpm
Required Salt Level: 4,000 ppm (4.0 gpl)
Maximum water volume treated:
APURE35 - 35,000 gal. (132,000 L)
Chlorine Output:
APURE35 -
0.62 oz. (17.5 g) per hour
Input Voltages: 240 V or 120 V (the system
auto-detects voltage)
Pool Return
Input Current @ 240 VAC: ~1 A
Input Current @ 120 VAC: ~1.3 A
Input Freq: 47~63 Hz
Output Voltage: 25V DC (max)
Output Current (adjustable by switch):
APURE35 - 5A DC
Dimensions:
Power Pack (L x W x H): 10 in. x 4.5 in. x 13 in.
Electrolytic Cell (L x W x H): 6.5 in. x 5.5 in. x 12 in.
Weight:
Power Pack: 7 lbs.
Electrolytic Cell: 2 lbs.
Power Pack
Filter
Pool Intake
Spa Return
To common
power source
Pump
Spa Intake

Hide quick links: