Output device operation check table
Step Operating device
1
Blower motor
speed
2
Air mi actuator
operation
3
Airflow mode
actuator operation
4
Air intake actuator
operation
A/C compressor
operation
*
: Shown on the information display according to step.
End Of Sie
CONTROL SYSTEM
Operating conditions
Moni
Other device conditions
*
tor
• Air mi actuator operation
— 50%
• Airflow mode actuator operation
— VENT
• Air intake actuator operation
— FRESH
• A/C compressor operation
1
— ON
• Blower motor speed
— 3rd
21.0
• Airflow mode actuator operation
— VENT
• Air intake actuator operation
— FRESH
• A/C compressor operation
20.5
— ON
20.0
• Blower motor speed
— 3rd
• Air mi actuator operation
— 50%
• Air intake actuator operation
— FRESH
• A/C compressor operation
3
— ON
• Blower motor speed
— 3rd
• Air mi actuator operation
— 0%
• Airflow mode actuator operation
— VENT
4
U