Diagnostic trouble codes
DTC
Indicator pattern
No.
02
06
07
10
11
12
13
14
15
18
19
21
22
58
59
Output Device Operation Check Mode
• In the output device operation check mode, the climate control unit forces all the output system actuation
devices to operate regardless of the input system. The displays change and the switch indicator lights
illuminate automatically according to the actuator operated.
• Inspect visually, listen for operation sound, and place hands over air discharge outlets to check for correct
operating conditions and to locate the malfunctioning system.
U–38
CONTROL SYSTEM
Diagnosed circuit
Solar radiation sensor
(present)
Cabin temperature
sensor (present)
Cabin temperature
sensor (past)
Evaporator temperature
sensor (present)
Evaporator temperature
sensor (past)
Ambient temperature
sensor (present)
Ambient temperature
sensor (past)
Water temperature
sensor (present)
Water temperature
sensor (past)
Air mi actuator
(potentiometer)
(present)
Air mi actuator
(potentiometer) (past)
Airflow mode actuator
(potentiometer)
(present)
Airflow mode actuator
(potentiometer) ((past)
Air mi actuator (motor
lock) (past)
Airflow mode actuator
(motor lock) (past)
Detected condition
Open circuit in solar radiation sensor
circuit
Short circuit in solar radiation sensor
circuit (terminal B side only)
Open/short circuit is in cabin
temperature sensor circuit
Cabin temperature sensor circuit is
entered fail-safe mode at least once
Open/short circuit is in evaporator
temperature sensor circuit
Evaporator temperature sensor
circuit is entered fail-safe mode at
least once
Open/short circuit is in Ambient
temperature sensor circuit
Ambient temperature sensor circuit
is entered fail-safe mode at least
once
Open/short circuit is in Water
temperature sensor circuit
Water temperature sensor circuit is
entered fail-safe mode at least once
Open/short circuit is in air mi
actuator (potentiometer) circuit
Air mi actuator (potentiometer)
circuit is entered fail-safe mode at
least once
Open/short circuit is in airflow mode
actuator (potentiometer) circuit
Airflow mode actuator
(potentiometer) circuit is entered fail-
safe mode at least once
Air mi actuator circuit is entered fail-
safe mode at least once
Airflow mode actuator circuit is
entered fail-safe mode at least once
Memo
rized
No
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
Yes
Yes