Main Control Programming Options

Fault Recall Mode
Whenever the A2 Control Board Assembly detects an electrical system error or fault, one or more error
codes are displayed and stored by the A2 Control Board Assembly You can recall error codes (if any) from
previous machine operation for troubleshooting purposes, To recall stored error codes:
1
Turn the key switch off.
2
Press and hold the solution switch
3
While holding the solution switch, turn the key switch on.
4
Continue to hold the solution switch until the solution system indicator turns on
5
Release the solution switch The solution system indicator turns off and the scrub off indicator will light
The display will show a wrench icon indicating that you are in fault recall mode
• If there are no previous error codes stored, the display will show the no-fault wrench icon
asking you to reset the machine (no fault). Skip to step 7.
• If error codes have been stored, the display will show the wrench icon and error number(s) next to the
wrench If more than one error code is stored, the display will toggle through all the errors stored
6. • If you want to save the codes, skip to step 7.
• To clear the stored error codes, press the scrub off switch. The display will now show key switch icon
asking you to reset the machine.
7.
To exit the fault recall mode, turn the key switch off.
To Restore the Scrub Pressures to the Factory Default Settings
1
Turn the key switch off.
2
Press and hold the scrub on switch
3
While holding the scrub on switch, turn the key switch on.
4
Continue to hold the scrub on switch until the display shows key switch icon. The factory default scrub
pressures have now been restored
5
Turn the key switch off.
To Enable/Disable the Fault Detection
Note that the factory default for fault detection is ON
Normally the main control unit will perform checks of the electrical system during operation. If a fault
occurs in a particular system, that system (and possibly others) will be shut down. This can make
troubleshooting the system difficult. This option will allow service personnel to disable some of the fault
detection checks to facilitate troubleshooting. This will not disable the over-current protection on any of the
systems. To turn the fault checking on or off:
1
Turn the key switch off.
2
Press and hold both the scrub off switch and solution switch
EcoFlex
, BR 1100/1300 EcoFlex
Control System
28