Using The Cmos Setup Utility; Using The Main Window - IBM Models 5 Service Manual

Anyplace kiosk series
Table of Contents

Advertisement

Diagnosing problems and troubleshooting
Condition description
Unacceptable image quality
Magnetic stripe reader (MSR) malfunctioning 1. Check that the cable is securely
Tabletop mount tilts too easily
Note: ¹A corrupted CMOS can cause unpredictable problems. Before exchanging

Using the CMOS Setup Utility

Follow these steps to start the CMOS Setup Utility:
1. Switch the power ON.
2. Press Del during POST when prompted, or tap the touch screen two times.
Figure 43 on page 69 is an example of the initial panel that is displayed in the
CMOS Setup Utility.

Using the Main window

Use the Main window (Figure 43 on page 69) to access the various features of the
CMOS utility. The navigation tool bar is located at the bottom of the screen.
68
IBM AnyPlace Kiosk 4838
the system board to resolve a problem, go to "Clearing the CMOS settings"
on page 70 and reset CMOS. Clearing CMOS ensures that all BIOS settings
are configured to a known, functional state.
Use the keys listed in the legend bar at the bottom of the screen to make your
selections or exit from the current menu. The help window on the right side of
each menu displays the online help information for the currently selected item.
Resolution
1. Ensure that the video mode is set for
1024 x 768 (15 inch models), or 1280 x
1024 (17 and 19 inch models).
2. Run the diagnostics. See "Using the IBM
diagnostics for POS systems and
peripherals package" on page 71.
connected.
2. Run the MSR test using the service
diskette.
3. Replace the MSR.
1. Check the force necessary to tilt the
display when pressing at the top of the
LCD. It should be at least 2.2 kg (5 lb.).
2. If the tilt force is not at least 2.2 kg (5 lb.),
replace the mount.