Recovering An Error Situation In 'Account Logging - Oce 31x5E Configuration And Maintenance Manual

Hide thumbs Also See for 31x5E:
Table of Contents

Advertisement

Recovering an error situation in 'Account logging'

Error recovery in 'Account logging' always starts in the 'Hold jobs' mode. The
connection to the DAC may be lost. You may want to set the mode to continue
to enable the execution of jobs in the key operator mode.
Hold jobs mode
its memory if it is written to the log file. The memory buffer in 'Account
logging' can hold a maximum number of 25 jobs. If an error occurs, 'Account
logging' will continue executing jobs and collecting information until this
maximum of 25 jobs has been reached. After this, the Océ 31x5E stops
executing jobs. The information in memory will be transferred to the log file
on the DAC as soon as the error situation is recovered.
If the maximum number of jobs in memory is reached in 'Hold jobs'
Note:
mode, you can switch to 'Ignore error' mode to continue executing jobs.
Ignore error mode
reached, the information of the job at the bottom of the list will be overwritten
and lost. However the execution of jobs on the Océ 31x5E will continue. After
recovering the error, the 'Account logging' information is transferred to the log
file on the DAC.
The 'Account logging' mode will always switch back to the 'Hold jobs'
Note:
mode.
Information about some jobs may be missing, depending on the number of jobs
that were executed during the error situation.
Information will only be lost if the number of executed jobs was greater
Note:
than 25.
20
Océ 31x5E Configuration and special maintenance
(default) 'Account logging' only removes information from
After the maximum number of 25 jobs in memory has been

Advertisement

Table of Contents
loading