Code
Contents
F000
Main PWB - operation PWB
communication error
F010
Main PWB checksum error
F020
Main PWB RAM checksum
error
F040
Main PWB - print engine
communication error
F050
Print engine ROM check-
sum error
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Operation PWB and engine PWB (YC17)
Defective main
Turn the main power switch off/on to restart
PWB.
the machine. If the error is not resolved,
replace main PWB (see page 1-5-22).
Defective opera-
Replace the operation PWB and check for
tion PWB.
correct operation.
Defective main
Turn the main power switch off/on to restart
PWB.
the machine. If the error is not resolved,
replace main PWB (see page 1-5-22).
Defective main
Turn the main power switch off/on to restart
memory (RAM) in
the machine. If the error is not resolved,
main PWB
replace main PWB (see page 1-5-22).
Defective
Replace the expansion memory (DIMM).
expended memory
(See Page 1-2-12)
(DIMM)
Also in the case of the capacity besides
specification, it displays.
Defective main
Turn the main power switch off/on to restart
PWB.
the machine. If the error is not resolved,
replace main PWB (see page 1-5-22).
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-22).
Defective engine
Turn the main power switch off/on to restart
PWB.
the machine. If the error is not resolved,
replace engine PWB (see page 1-5-22).