Kyocera ECOSYS FS-4300DN Service Manual page 168

Hide thumbs Also See for ECOSYS FS-4300DN:
Table of Contents

Advertisement

Connector
Pin
YC1
1
EECLK
Connected to
2
GND
the engine
3
EESIO
PWB
4
ERASER
5
+3.3V6
6
TSENS
7
SBMDIR
8
WTSENS
9
SBMENBLN
10
WTLED
11
SBMSTEP
12
MEFSENS
13
SBMMODE
14
+3.3V2
15
TMOT
16
LFANN
17
FUDR
18
ENVMOT
19
FDDR
20
DUJAMSEN1
N
21
REGSEN2
22
REARSWN
YC2
1
+24V6
Connected to
2
GND
the engine
3
GND
PWB
4
+24V4
YC3
1
TSENS
Connected to
2
+24V6
the drum
3
ERASERN
connect
4
EECLK
PWB
5
EESIO
6
TMOT
7
+3.3V6
8
GND
9
REGSEN2
Signal
I/O
I
0/3.3 V DC(pulse)
-
-
I/O
0/3.3 V DC
I
0/3.3 V DC
I
3.3 V DC
O
Analog
I
0/5 V DC
O
Analog
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC
I
3.3 V DC
I
0/3.3 V DC
I
0/24 V DC
I
0/24 V DC
I
0/5 V DC
I
0/24 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
I
24 V DC
-
-
I
24 V DC
I
Analog
O
24 V DC
O
0/24 V DC
O
0/24 V DC(pulse)
I/O
0/3.3 V DC
O
0/5 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
Voltage
Clock signal
Ground
Data signal
CL control signal
3.3 V DC power input from EPWB
TS output signal
SBM: On/Off
WTS output signal
SBM output control signal
Waste toner LED control
SBM step signal
MPS: On/Off
SBM mode control signal
3.3 V DC power input from EPWB
TM: On/Off
LFM: On/Off
FSSOL: On/Off
ENVM: On/Off
FSSOL: On/Off
DUS1: On/Off
RS2: On/ Off
RECSW: On/Off
24 V DC power input from EPWB
Ground
Ground
24 V DC power input from EPWB
TS output signal
24 V DC power output to DRRPWB
CL: On/Off
Clock signal
Data signal
TM control signal
3.3 V DC power output to DRRPWB
Ground
RS2: On/Off
2-3-16
2LV/2L1/2L2/2MS/2MT
Description

Hide quick links:

Advertisement

Table of Contents
loading