Kyocera ECOSYS FS-4300DN Service Manual page 159

Hide thumbs Also See for ECOSYS FS-4300DN:
Table of Contents

Advertisement

Connector
Pin
YC1
1
HEAT2REM
Connected to
2
HEAT1REM
the power
3
ZCROSSN
source PWB
4
RELAY
5
PSLEEPN
*: 60/50/45
ppm model
6
GND
only
7
GND
8
GND
9
GND
10
+24V1
11
+24V1
12
+24V1
13
+24V1
YC2
1
EECLK
Connected to
2
GND
the relay-L
3
EESIO
PWB
4
ERASER
5
+3.3V6
*: 60/50/45
ppm model
6
TSENS
only
7
SBMDIR
8
WTSENS
9
SBMENBLN
10
WTLED
11
SBMSTEP
12
MEFSENS
13
SBMMODE
14
+3.3V2
15
TMOT
16
LFANN
17
FUDR
18
ENVMOT
19
FDDR
20
DUJAMSEN1
N
21
REGSEN2
22
REARSWN
Signal
I/O
O
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
-
-
-
-
-
-
-
-
I
24 V DC
I
24 V DC
I
24 V DC
I
24 V DC
O
0/3.3 V DC
-
-
I/O
0/3.3 V DC(pulse)
O
0/3.3 V DC
O
3.3 V DC
I
Analog
O
0/3.3 V DC
I
Analog
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC(pulse)
I
0/3.3 V DC
O
0/3.3 V DC
O
3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
Voltage
TH2 remote signal
TH1 remote signal
Zero crossing detection signal
Relay driving signal
Sleep signal
Ground
Ground
Ground
Ground
24 V DC power input from PSPWB
24 V DC power input from PSPWB
24 V DC power input from PSPWB
24 V DC power input from PSPWB
Clock signal
Ground
Communication data
CL: On/Off
3.3 V DC power output to R-LPWB
TS output signal
SBM: On/Off
WTS output signal
SBM enable signal
LED: On/Off
SBM clock signal
MPS: On/Off
SBM mode signal
3.3 V DC power output
TM: On/Off
CENFM: On/Off
FSSOL: On/Off
FUPRM: On/Off
FSSOL: On/Off
DUS: On/Off
RS: On/Off
RCS: On/Off
2-3-7
2LV/2L1/2L2/2MS/2MT
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents