Real TIMe eVenT
Use the serial command RTE to specify an action that is initiated at a particular time or based
on an external stimulus.
For General Purpose IO "G"
Parameter
name
P1
RTE type
P2
I/O bit
P3
Pin state
(1 Character)
(String)
P4
Commands
example 2. Projector powers up when a switch on the external device is turned on.
(GIO C2 I)
(RTE G 2 H "(PWR 1)")
(RTE G 2 L "(PWR 0)")
D-2
Value
G (Real Time I/O Event)
1-7
H = High
L = Low
"LHXXXHL" Combine multiple inputs and trigger occurs
when all conditions are met
Any valid serial protocol command for the device
Set pin #2 configuration as input
Power on when pin #2 set to high
Power off when pin #2 set to low
Appendix D ► System Integration