Front Panel Features
Power
1
SWP-2000 front panel features
FIGURE 5.
Power LED. Indicates that the SWP-2000 has power.
1.
TM/MTM A Status LEDs. Indications for: Activity, Active TM/MTM, Standby TM/MTM, Other TM/MTM. The
2.
Activity LED indicates activity on the TM-2000/MTM-2000 associated with the TM/MTM A inputs. Active TM/MTM
LED indicates activity on the TM-2000/MTM-2000 (either A or B) is active.
Standby TM/MTM LED indicates which TM-2000/MTM-2000 (either A or B) is in standby. Other TM/MTM LED
indicates green if TM/MTM B is talking, red if not, and off if the system is not configured for a backup TM-2000/MTM-
2000.
TM/MTM A Go Active Control Switch. Forces the TM-2000/MTM-2000 associated with the TM A inputs to become the
3.
active trunk master.
TM/MTM B Status LEDs. Indications for: Activity, Active TM/MTM, Standby TM/MTM, Other TM/MTM. The
4.
Activity LED indicates activity on the TM-2000/MTM-2000 associated with the TM/MTM B inputs. Active TM/MTM
LED indicates which TM-2000/MTM-2000 (either A or B) is active. Standby TM/MTM LED indicates which TM-
2000/MTM-2000 (either A or B) is standby. Other TM/MTM LED indicates green if TM/MTM A is talking, red if not,
and off if the system is not configured for a backup TM-2000/MTM-2000.
TM/MTM B Go Active Control Switch: Forces the TM-2000/MTM-2000 associated with the TM/MTM B inputs to
5.
become the active trunk master.
Rear Panel Features
100-240 VAC
1
SWP-2000 rear panel features
FIGURE 6.
AC Power.
1.
TrunkSupervisor Connector. Provides connection to the COM port of the external PC running TrunkSupervisor
2.
software.
TrunkEdit Connector. Provides connection to the COM port of the extra PC running TrunkEdit software.
3.
Trunk Master A TrunkSupervisor connector. Connects to COM port 2 of the TM-2000/MTM-2000 assigned to be Trunk
4.
Master A.
Trunk Master A TrunkEdit connector. Connects to COM port 1 of the TM-2000/MTM-2000 assigned to be Trunk Master
5.
A.
Trunk Master A parallel port. Connects to parallel printer port of the TM-2000/MTM-2000 assigned to be Trunk Master
6.
A. Provides control from the SWP-2000 to the TM-2000/MTM-2000 and LED status monitoring of the TM-2000/
MTM-2000 and LED status monitoring of the TM-2000/MTM-2000 on the SWP-2000 front panel.
Trunk Master B TrunkSupervisor connector. Connects to COM port 2 of the TM-2000/MTM-2000 assigned to be Trunk
7.
Master B.
TM A
Activity
Active TM
Standby TM
Other TM
Go Active
3
4
2
OUTPUT
TRK SPVR
TRK EDIT
TRK SPVR
TRK EDIT
2
3
4
5
TM B
Activity
Active TM
Standby TM
Other TM
Go Active
5
TM B INPUT
PP
TRK SPVR
6
7
TM
SWP-2000
TM A INPUT
TRK EDIT
PP
8
9
7