Emerson FXMP25 User Manual page 48

Field controller
Table of Contents

Advertisement

Table 7-2 Quick start commissioning / start up from defaults for Mentor MP mode
Action
Ensure:
Before power up
Ensure:
Power up the field
controller
To select MP mode
Select Mentor MP
mode
The Mentor MP has taken control of the FXMP25. Setting up
Setting up the field
should now be carried out using the Mentor MP. Please refer to
controller
the running a motor section in Mentor MP Short Form Guide.
Setting in MP
Set Pr 5.78 to EXTERNAL
48
Motor field is connected.
The MP port on the FXMP25 is connected to the external
field controller port on the Mentor MP using a shielded
straight through RJ45 to RJ45 lead, maximum length 100 m.
Mentor MP software must be V01.05.01 or later.
The field controller displays:
If the field controller trips, see Chapter 9
page 60.
Set Pr 78 (Field mode) = MP (1)
Press the mode button to enter parameter view mode
Press and hold the mode button for at least 2 seconds to
carry out a reset.
www.controltechniques.com
Detail
on
Diagnostics
FXMP25 User Guide
Issue Number: 3