Emerson FXMP25 User Manual page 42

Field controller
Table of Contents

Advertisement

90
91
92
93
Coding
Range
Update rate
Indicates the last four field controller trips.
94
Coding
Range
Default
Update rate
This parameter defines which parameter is displayed at power up. When the field
controller enters status mode this parameter is also displayed.
95
Coding
Range
Default
Update rate
Used to define the unique address for the field controller for the serial interface. The
field controller is always a slave.
Addresses between 0 and 247 are permitted. Address 0 is used to globally address all
slaves, and so this address should not be set in this parameter.
96
Coding
Range
Default
Update rate
Used to define the baud rate of the serial interface.
Parameter value
42
Trip 0
Trip 1
Trip 2
Trip 3
Bit
FI
Txt
1
0 to 255
Background write
Parameter displayed at power-up
Bit
FI
Txt
00 to 98
54
Background read
Serial address
Bit
FI
Txt
0 to 247
1
Background read
Baud rate
Bit
FI
Txt
1
0 to 4
3
Background read
String/baud rate
0
1
2
3
4
www.controltechniques.com
VM
DP
ND
1
VM
DP
ND
VM
DP
ND
VM
DP
ND
2400
4800
9600
19200
38400
US
RW
BU
1
US
RW
BU
1
1
1
US
RW
BU
1
1
1
US
RW
BU
1
1
1
FXMP25 User Guide
Issue Number: 3
PS
1
PS