Emerson FXMP25 User Manual page 24

Field controller
Table of Contents

Advertisement

4
5 (+10V)
Function
Voltage tolerance
Rated output current
Protection
6 (If)
7 (Va)
Type
Voltage range
Maximum output current
Load resistance
Protection
Resolution
Update period
8
9
10
Function
Type
Rating
Contact condition
Update period
Status relay contact is over-voltage category II.
WARNING
24
Not used
10V user output
Field current output signal
Armature voltage output signal
Fail relay common
Fail relay normally open
Fail relay normally closed
www.controltechniques.com
Supply for Analog input terminal
2 %
5 mA
Over 5 mA, the current is limited, but
there is no trip (Voltage is less than 10 V
if the current is higher than 5 mA)
Single-ended voltage
0 to 10 V
5 mA
2 kΩ min
5 mA short circuit protection
10 bits
4 ms
FXMP25 OK indicator (See Pr 01 and
Pr 27.
Form C
250/125 Vac category 1/2
5 A nominal resistive load
5 A 30 Vdc
Energized when power applied and
FXMP25 OK
4 ms
FXMP25 User Guide
Issue Number: 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents