Emerson FXMP25 User Manual page 32

Field controller
Table of Contents

Advertisement

02
Coding
Range
Update rate
The average measured DC input voltage seen across the field controller A1 and A2
terminals.
03
Coding
Range
Update rate
This parameter displays the level of the analog signal present at the flux reference input,
this is a unipolar voltage input where the input range is 0 V to +10 V.
04
Coding
Range
Default
Update rate
An offset can be added to flux reference input with a range from -100.0 % to 100.0 %. If
the sum of the input and the offset is outside the range 0 to 100 % the result will be
clamped at 0 or 100 %.
05
Coding
Range
Default
Update rate
The flux reference input is connected to the field economy parameter when the flux
input is selected. The maximum value of the field economy is 100 % and so the default
for the scaling parameter is 1 so that the demand is 100 % for 10 V input.
06
Coding
Range
Default
Update rate
The maximum value of Pr 02 is 860 which without any scaling will be converted to 10 V.
This parameter should be adjusted by the user for other full scale voltages.
32
Armature voltage
Bit
FI
Txt
1
0 to 860 V
Background write
Flux reference
Bit
FI
Txt
1
0.0 to 100.0 %
Background
Flux reference input offset
Bit
FI
Txt
±100 %
0.0
Background read
Flux reference scaling
Bit
FI
Txt
0.000 to 4.000
1.000
Background
Armature voltage output scaling
Bit
FI
Txt
0.000 to 4.000
1.000
Background
www.controltechniques.com
VM
DP
ND
US
1
VM
DP
ND
US
1
1
VM
DP
ND
US
1
VM
DP
ND
US
3
VM
DP
ND
US
3
RW
BU
PS
1
RW
BU
PS
1
RW
BU
PS
1
1
RW
BU
PS
1
1
1
RW
BU
PS
1
1
1
FXMP25 User Guide