Received Del; Private Mode; Pos. On Bc/Ovrsz; Bc Check Digit - IBM 6500 User Manual

Infoprint 6500 line matrix printers cabinet and pedestal models
Hide thumbs Also See for 6500:
Table of Contents

Advertisement

Received DEL

v Observe (the default). A DEL code received from the host is handled as a Delete
v

Private Mode

Determines the default type of character set (Set 1 or Set 2). This can also be set by
ESC sequences ESC [>5h and ESC [>5l. Refer to these descriptions in the ANSI
Programmer's Reference Manual for further details.
v Set 2 (the default)
v Set 1

Pos. on BC/OvrSz

v Set to Top (the default). The paper is fed back to the top of barcodes or
v Set to Bottom . The printer will continue printing without backing up.

BC Check Digit

v By Host (the default). The host calculates the barcode check digit and sends it
v By Printer. The barcode is sent without the check digit, and the printer

Barcode Darkmode

v Enable (the default). The barcodes are printed at a higher resolution.
v Disable. The barcodes are printed at lower resolution but at a higher speed.

PUM Default

This is the Unit of Measure (UOM) as it is used within the ANSI emulation.
Coordinates received in ESC sequences can be sent in two UOMs: Decipoints,
which is a unit of 1/720 inch, or in lines or columns using the current LPI and CPI
values. The UOM used is determined by this configuration setting.
v Decipoints (the default)
v Lines/Columns

Truncate PI Slew

v Truncate at TOF (the default). The slew is terminated when the next Top-of-
v Disable. PI slews will be completed independent of their length.
160
Infoprint 6500 User's Manual
command.
Ignore. A DEL code received from the host is ignored.
oversized characters after they are printed. This allows printing on the same
line.
along with the barcode. The check digit is not verified by the printer but printed
as it was received.
calculates and adds it in.
Form is reached. (This function applies to the ANSI EVFU only).

Advertisement

Table of Contents
loading

Table of Contents