Engine

Refitting the ub cover

- Refit the whole wheel axle.
- Refit the intermediate gear paying attention to the
two shim thicknesses.
- Apply LOCTITE 510 for surfaces to the hub cov-
ers and refit the same with driven pulley shaft.
- Refit the 5 screws and tighten them to the speci-
fied torque.
N.B.
CLEAN THE CONTACT SURFACES OF THE HUB COVER
AND THE HALF CRANKCASE OF RESIDUE FROM PREVI-
OUS GASKETS BEFORE APPLYING A NEW ONE.
Locking torques (N*m)
Locking torque:
11 to 13 Nm

Flywheel cover

Removing the stator

- Remove the three stator fixings shown in the
photo
- Remove the two pick-up fixings shown in the
photo
- Remove the stator with the wiring
ENG - 80