124 | Maintenance and Troubleshooting

Cleaning the MC67

Housing
Using the alcohol wipes, wipe the housing including buttons.
Display
The display can be wiped down with the alcohol wipes, but care should be taken not to allow any pooling of liquid
around the edges of the display. Immediately dry the display with a soft, non-abrasive cloth to prevent streaking.
Camera and Exit Window
Wipe the camera and exit window periodically with a lens tissue or other material suitable for cleaning optical
material such as eyeglasses.

Cleaning Cradle Connectors

To clean the connectors on a cradle:
Procedure:
1 Remove the DC power cable from the cradle.
2 Dip the cotton portion of the cotton-tipped applicator in isopropyl alcohol.
3 Rub the cotton portion of the cotton-tipped applicator along the pins of the connector. Slowly move the applicator
back-and-forth from one side of the connector to the other. Do not leave any cotton residue on the connector.
4 All sides of the connector should also be rubbed with the cotton-tipped applicator.
Caution: Do not point nozzle at yourself and others, ensure the nozzle or tube is pointed away from
your face.
5 Spray compressed air in the connector area by pointing the tube/nozzle about ½ inch away from the surface.
6 Remove any lint left by the cotton-tipped applicator.
7 If grease and other dirt can be found on other areas of the cradle, use a lint-free cloth and alcohol to remove.
8 Allow at least 10 to 30 minutes (depending on ambient temperature and humidity) for the alcohol to air dry before
applying power to cradle.
If the temperature is low and humidity is high, longer drying time is required. Warm temperature and dry humidity
requires less drying time.

Troubleshooting

The following tables provides typical problems that might arise and the solution for correcting the problem.

MC67

Table 14: Troubleshooting the MC67

Problem
When pressing the
power button the
MC67 does not turn
on.
Send Feedback
| January 2014 | MN000115A01
Cause
Battery not charged.
Battery not installed
properly.
System crash.
Solution
Charge or replace the battery in the MC67.
Install the battery properly. See
27.
Perform a reset. See
Resetting the Device on page
Installing the Battery on page
51.
Table continued...