Minimum Clearances To Combustibles - Quadra-Fire 7100FP-GD-B Installation Manual

Epa certified woodburning fireplace
Hide thumbs Also See for 7100FP-GD-B:
Table of Contents

Advertisement

1. Minimum Clearances to Combustibles

WITHIN ENCLOSURE AREA
Fireplace to backwall
Fireplace to sidewall
Duct boots to framing
Top standoffs to header
Door opening to sidewall
EXPOSED SURFACES
Faceplate to sidewall
Heat zone air grills to ceiling 12 in. (305 mm)
MANTEL
Non-combustible mantel
(Non-combustible framing
materials above the fireplace
to ceiling)
Combustible mantel
(Combustible framing
materials above the fireplace
to ceiling)
Maximum mantel depth
2 in.
(51 mm)
46-1/4 in.
(1175 mm)
24 in.
(610 mm)
The finished cavity depth must
be no less than 24 in. (610 mm)
from the finished backwall to
the outside of front wall framing.
Figure 3.3
Framing the Fireplace
12
1 in. (25 mm)
1 in. (25 mm)
0 in. (0 mm)
0 in. (0 mm)
22-7/8 in. (581 mm)
16 in. (406 mm)
46 in. (1168 mm)
60 in. (1524 mm)
12 in. (305 mm)
12 in.
(305 mm)
Position combustible/
non-combustible mantel
60 in. (1524 mm) from
base of fireplace
42-1/4 in.
(1073 mm)
48-1/4 in.
(1226 mm)
Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev G • 5/27/14