Quadra-Fire 4100I-GD-B Manual
Quadra-Fire 4100I-GD-B Manual

Quadra-Fire 4100I-GD-B Manual

Wood insert advanced combustion technology (act)
Hide thumbs Also See for 4100I-GD-B:

Advertisement

Models:
4100I-GD-B
4100I-NL-B
Important operating
a n d m a i n t e n a n c e
instructions included.
If the information in these
instructions is not followed
exactly, a fi re may result causing
property damage, personal injury,
or death.
• Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
• Do not overfi re - If heater or chimney
connector glows, you are overfi ring.
Overfi ring will void your warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
Installation and service of this appliance should
be performed by qualifi ed personnel. Hearth &
Home Technologies recommends NFI certifi ed
professionals, or technicians supervised by an
NFI certifi ed professional.
1445 North Highway
Colville, WA 99114-2008
4100- I ACT WOOD INSERT
Advanced Combustion Technology (ACT)
DO NOT DISCARD THIS MANUAL
• Read, understand and
follow these instructions
for safe installation and
operation.
WARNING
250-7201D
NOTICE
• Leave this manual with
party responsible for
use and operation.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in the same room
as appliance
• Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
fl ammable materials.
• Keep clothing, furniture, draperies and other
combustibles away.
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfi re and generate
poisonous gases (i.e. carbon monoxide).
March 27, 2008
R
Tested and
Beaverton
O-T
O-T L
Oregon USA
Listed by
C
US
OMNI-Test Laboratories, Inc.
WARNING
HOT SURFACES!
G L A S S A N D O T H E R
S U R FA C E S A R E H O T
DURING OPERATION AND
COOL DOWN.
WARNING
www.quadrafi re.com

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire 4100I-GD-B

  • Page 1 4100- I ACT WOOD INSERT Advanced Combustion Technology (ACT) Models: 4100I-GD-B 4100I-NL-B Tested and Beaverton O-T L Oregon USA Listed by OMNI-Test Laboratories, Inc. NOTICE DO NOT DISCARD THIS MANUAL • • Read, understand and • Leave this manual with...
  • Page 2 Hearth & Home Technologies welcomes you to our tradition hand-fi nished for lasting beauty and enjoyment. Our pledge of excellence! In choosing a Quadra-Fire appliance, you to quality is completed as each model undergoes a quality have our assurance of commitment to quality, durability, and control inspection.
  • Page 3: Table Of Contents

    4100-I ACT WOOD INSERT Table of Contents SAFETY & OVERVIEW OF APPLIANCE MAINTENANCE Dimensions ----------------------------------------------------- 4 Gold/Nickel Plated Surfaces ------------------------------- 20 Minimum Clearances to Combustibles ------------------ 5 Glass Cleaning & Replacement --------------------------- 20 Listings ---------------------------------------------------------- 6 Creosote Formation & Removal -------------------------- 20 Chimney Height &...
  • Page 4: Dimensions

    4100-I ACT WOOD INSERT DIMENSIONS 30" (762mm) 24" (610mm) 16-1/4" (413mm) 12-1/8" 9-5/16" (308mm) (135mm) 7-7/8" (200mm) SIDE VIEW TOP VIEW 21-5/8" 20-7/8" (549mm) (530mm) 10-7/8" (276mm) FRONT VIEW 45-3/4" (1162mm) Panel Size Standard 44-3/4” 30-1/2” (1137mm) (775mm) Large 48” 34”...
  • Page 5: Minimum Clearances To Combustibles

    4100-I ACT WOOD INSERT CLEARANCES TO COMBUSTIBLES United States and Canada Maximum Mantel Depth - 10" (254mm) Mantel Fascia or Trim Insert Hearth Extension Omni Report #061-S-40-2 CANADA Sidewall to Stove 15" (381mm) 15" (381mm) Mantel to Stove 26" (660mm) 23"...
  • Page 6: Listings

    INSTALLATION RECOMMENDATIONS CHIMNEY HEIGHT/DRAFT This product has met and surpassed the most stringent emissions To be sure that your Quadra-Fire insert burns properly, the standards in the United States. The sophistication of the interior chimney draft (static pressure) should be approximately fi...
  • Page 7: General Installation Procedures

    4100-I ACT WOOD INSERT CALCULATING ALTERNATE FLOOR GENERAL INSTALLATION PROCEDURE PROTECTION MATERIAL • DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. Thermal Conductivity: k value • Install liner, if required, for your chosen installation. The k value indicates the amount of heat (in BTU’s) that will fl ow •...
  • Page 8: Chimney Requirements

    4100-I ACT WOOD INSERT OVALIZING ROUND STAINLESS STEEL CHIMNEY REQUIREMENTS LINERS A chimney must be the required height above the roof or other obstruction for safety and for proper draft oper- Ovalizing round stainless steel liners to accommodate the liner passing through the damper region of a fi re- ation.
  • Page 9: Mobile Home

    4100-I ACT WOOD INSERT INSTALLATIONS INTO ZERO CLEARANCE FIREPLACES IN MOBILE HOMES Spark Arestor Cap (IN USA ONLY) An outside air inlet must be provided for combustion and must Storm Collar remain clear of leaves, debris, ice and/or snow. It must be unrestricted while unit is in use to prevent room air starvation Roof Flashing which can cause smoke spillage and an inability to maintain a...
  • Page 10: Masonry Fireplace

    4100-I ACT WOOD INSERT INSTALLATION OPTIONS Refer to: Clearances to Combustibles on page 5, Canadian Installation requirements on page 12, Hearth Requirements on page 5 and Zero Clearance Adjustable Support Kit on page 16. MASONRY FIREPLACE USING DIRECT-CONNECT METHOD Masonry Chimney Flue Tile This product conforms with the UL Standard for Safety 1482 (USA) and ULC S628 (Canada) in all respects, and...
  • Page 11: Factory-Built Zero Clearance Fireplace

    FACTORY-BUILT ZERO CLEARANCE FIREPLACE (USA INSTALLATIONS ONLY) The Quadra-Fire 4100-I Insert is listed to UL 1482 Standard and is approved for installation into listed factory-built zero clearance fi replaces listed to UL 127 conforming to the following specifi cations and instructions:...
  • Page 12: Canadian Masonry & Heat Circulating

    4100-I ACT WOOD INSERT INSTALLATION IN CANADA MASONRY and HEAT-CIRCULATING (INSTALLATIONS INTO FACTORY-BUILT FIREPLACES ARE PROHIBITED IN CANADA) Whether installed in a masonry or heat-circulating fi replace, this fi replace insert must be installed with a continuous chim- ney liner of six inch (152mm) diameter extending from the fi replace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirements of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or Factory-Built Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.
  • Page 13: Securing Liner To Chimney Ring

    4100-I ACT WOOD INSERT SECURING LINER TO CHIMNEY RING There are two options to secure the liner to the chim- ney ring: See Figure 13A. Option One: If there is enough room on the top of the 2 pre-drilled holes on insert to work, hand bend the two tabs upward 90°.
  • Page 14: Panel Sets And Trim Sets

    4100-I ACT WOOD INSERT PANEL SET and CAST TRIM SET STANDARD SIZE: 30-1/2” h x 44-3/4”w LARGE SIZE: 34”h x 48”w Panel and Cast Trim must be ordered separately. Included in Panel Kit: (2) side panels, left and right; (1) panel top; (2) trim pieces; (1) trim top; (1) fastener package. Included in Cast Trim Kit: (2) cast trim legs, left and right;...
  • Page 15: Blower Cord Installation

    4100-I ACT WOOD INSERT BLOWER CORD LOCATION & BLOWER FAN (BLOWER) REPLACEMENT CONTROL BOX WITH SWITCH Included in Kit: Replacement Blower This insert comes standard with a blower, installed at the Tools Needed: 5-32 Wrench and Phillips Head Screwdriver. factory with blower cord on right side of insert (as you face the unit).
  • Page 16: Zero Clearance Adjustable Trim Support

    4100-I ACT WOOD INSERT ZERO CLEARANCE ADJUSTABLE TRIM SUPPORT Two sizes: 9”d x 45”w and 12”d x 50”w, both 2” to10” Height Adjustment Included in Kit: ( 1) Trim Top, (1) Trim Front, (2) Trim Sides, Double-Sided Tape (already installed) Tools Needed: Phillips Head Screwdriver, Sheet Metal Shears, Measuring Tape, Gloves 1.
  • Page 17: Wood Selection & Storing

    4100-I ACT WOOD INSERT OPERATION WOOD SELECTION AND STORAGE urn only dry seasoned wood. Dry, well-seasoned wood will not only minimize the chance of creosote formation but will give you the most effi cient heat output. Even dry wood contains at least 15% moisture by weight and should be burned hot enough to keep the chimney hot enough to maintain particulate (smoke) burning.
  • Page 18: Operating Tips

    HEAT OUTPUT RATES For maximum operating effi ciency with the lowest emissions, follow these operating procedures: Regardless of desired heat output, when loading insert, burn your Quadra-Fire with both air controls wide open for a minimum of 5 to 15 minutes.
  • Page 19: Burning Process

    In order to the burn. The coals burn with hot blue fl ames. improve the situation, we at Quadra-Fire have developed It is very important to reload your appliance while enough...
  • Page 20: Maintenance

    NOTE: Remove all labels from glass prior to lighting the fi rst fi re. Quadra-Fire inserts are equipped with super heat resistant ceramic glass which can only be broken by impact or misuse. Clean glass with any non-abrasive glass cleaner. Abrasive cleaners may scratch and cause glass to crack. Inspect glass regularly.
  • Page 21: Brick Replacement

    Call a qualifi ed chimney sweep or an authorized Quadra-Fire dealer for details. 1. Remove all ash from fi rebox, and extinguish all hot embers before disposal into a metal container.
  • Page 22: Exploded View

    4100-I ACT WOOD INSERT EXPLODED VIEWS 21-1/2" 10.0" 5.0" R5" 14.0" Ceramic Blanket Figure 22C Item Description Item Description Item Description Ashcatcher Baffl e, Fiberboard Flue Tab Blower, 180 cfm Ceramic Blanket, 1/2” Top, Cast Blower Mount Base Door Latch Box Assembly Brick (2) with holes Blower Housing, Cast Snap Disc 110 degree...
  • Page 23: Parts & Accessories List

    4100-I ACT WOOD INSERT Service Parts and Accessories IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on the Quadra-Fire web site at www. quadrafi re.com. When ordering, supply serial and model numbers to ensure correct part. Item Part Description...
  • Page 24 4100-I ACT WOOD INSERT Item Part Description Alphabetical Order Top, Cast 435-0300 Trim, Cast, Footer, Left 414-7090MBK Trim, Cast, Footer, Right 414-7100MBK Trim, Cast, Header 414-7110MBK Trim, Cast, Leg, Left 414-7120MBK Trim, Cast, Leg, Right 414-7130MBK Trim, Cast, Set, Matte Black (5 piece) 811-0930 Trim, Ring, Front, Gold 435-0570...
  • Page 25: Service & Maintenance Log

    4100-I ACT WOOD INSERT Service and Maintenance Log Date of Service Performed By Description of Service March 27, 2008 250-7201 Rev D Page 25...
  • Page 26 4100-I ACT WOOD INSERT Consumer’s Notes Page 26 March 27, 2008 250-7201 Rev D...
  • Page 27: Warranty Policy

    4100-I ACT WOOD INSERT Lifetime Warranty LIMITED LIFETIME WARRANTY The Hearth & Home Technologies limited Lifetime Warranty guarantees that the following components will work as designed for the life- time of the stove or Hearth & Home Technologies will repair or replace them. These items include but are not limited to steel and cast iron components, all gas burners, gas logs, combustion chambers, heat exchanger systems, stainless steel fi...
  • Page 28: Contact Information

    Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES www.quadrafi re.com Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer, call 1-800-926-4356 CAUTION • Do NOT discard this manual.

This manual is also suitable for:

4100i-nl-b4100-i act

Table of Contents