Roof Penetration; Manufactured Home Installation - Quadra-Fire 7100FP-GD-B Installation Manual

Epa certified woodburning fireplace
Hide thumbs Also See for 7100FP-GD-B:
Table of Contents

Advertisement

G. Roof Penetration
• Refer to Figure 6.10.
• Plumb from roof to center of chimney.
• Drive a nail up through roof to mark center of pipe.
• Measure to either side of nail and mark the 14-1/2 in. x
14-1/2 in. (368 mm x 368 mm) opening required.
• Measure opening on the horizontal; actual length may
be larger depending on roof pitch.
• Cut out and frame opening.
• Refer to Chapter 25 of the Uniform Building Code for
roof framing details.
Install Flashing
• Assemble chimney so it passes through the framed
opening.
• Slip the flashing over the chimney.
NOTICE:
Roofing shingles must be below the flashing
plate on the lower side of a sloped roof and over the
flashing plate on the sides and top.
• Nail the flashing to the roof. Keep gaps between the
flashing plate and the roof to a minimum.
• Caulk the flashing plate and roof junction as well as
the vertical seam on the flashing. All nail heads must
be caulked with a roofing sealant.
• Caulk the overlap seam of any exposed pipe sections
that are located above the roof line to prevent leaks.
H. Manufactured Home Installation
SL-300 Series Ceiling/Roof Thimble
NOTICE:
REQUIRED for manufactured homes.
• Locate the point where the chimney will exit the roof by
plumbing down to the center of the chimney. Lay out,
cut and frame a 14-1/2 in. (368 mm) square opening
(measured on the horizontal) through the ceiling and roof
structure. Consult local codes for framing details.
• The thimble must extend completely through the roof
structure shielding combustible materials. Five location
holes have been provided to allow for a variety of ceiling/
roof thicknesses. A thimble extension is required when
the ceiling/roof thickness exceeds 12-1/2 in. (318 mm).
The extension should overlap the thimble one inch.
• To attach the extension to the thimble, drill 1/8 in. (3 mm)
holes through the outer shield of the thimble using the
predrilled holes in the extension as guides. Attach the
extension to the thimble using the screws provided with
the extension.
• Install the thimble assembly and nail it securely to the
framing members.
32
Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev G • 5/27/14
Figure 6.10 Ceiling/Attic Construction
• Center the flashing over the chimney and nail it to the
roof. Keep gaps between the flashing plate and the roof
to a minimum. Caulk the flashing plate and roof junction
as well as the vertical seam on the flashing. All nail heads
must be caulked with a roofing sealant.
• Finish assembling the chimney storm collar and
termination cap following the installation instructions
provided with them.
FLASHING
Figure 6.11 Installing Part: 12966A, Configuration 1
CHIMNEY
FLASHING
PLATE
JOISTS
NAIL
THIMBLE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7100fp-bk-b7100fp-nl-b