Environmental Specifications; Electrical Specifications - Welch Allyn Scansteam 3400PDF User Manual

Table of Contents

Advertisement

Sectio 7
Product Specifications
SCANTEAM 3400PDF Product Specifications

Environmental Specifications

parameter
Operating Temperature
Storage Temperature
Humidity
Barometric Pressure
Mechanical Shock
ESD Sensitivity
Ambient Illumination
Modular Connector Life

Electrical Specifications

parameter
Operating Voltage
5VDC Input only
Current Draw (3400PDF/HD–2, –3)
Current Draw (3400PDF/LR–2, –3)
Standby Current
(3400PDF/HD)
(3400PDF/LR
In–Rush Current
Power Supply Noise Rejection
Acquisition Time (Trigger to Output)
Mean Time Between Failure (MTBF)
Agency Compliance
Patents
SCANTEAM 3400PDF User's Guide
specification
32 F to 122 F [0 C to 50 C]
–40 F to 158 F [–40 C to 70 C]
0% to 95% RH noncondensing
101,000 to 69,000 Pascals
[Sea level to 3,000 meters]
Functional after ten 5ft. [1.5m] drops
Functional after 15KV discharge
3400PDF/HD = 10,000 lux
750 insertions / disconnections
specification
5 VDC 10%
113 Scans/Sec 200 Scans/Sec
N/A
280mA
240mA
N/A
3mA
115mA
400mA maximum
100mV peak to peak,
from 10 to 100KHz
100msec maximum
50,000 hours (for ground benign)
FCC Class A, CE (Class A), LVD
U.S. 5,420,409
U.S. 5,723,853
7–1

Advertisement

Table of Contents
loading

Table of Contents