Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WAX MOTOR
Refer to page 4-8 for the procedure for servic-
ing the wax motor.
1.
Unplug dishwasher or disconnect power.
2.
Disconnect one of the wires from the wax
motor terminals.
3.
Set the ohmmeter to the R x 100 scale.
4.
Touch the ohmmeter test leads to the wax
motor terminals. The meter should indi-
cate between 600 and 1800 Ω.
WARNING
Electrical Shock Hazard
WATER INLET VALVE SOLENOID
Refer to page 4-13 for the procedure for servic-
ing the water inlet valve.
1.
Unplug dishwasher or disconnect power.
2.
Disconnect one of the wires from the water
inlet valve solenoid terminals.
3.
Set the ohmmeter to the R x 100 scale.
4.
Touch the ohmmeter test leads to the
water inlet valve solenoid terminals. The
meter should indicate between 890 and
1090 Ω.
5-3