Eclipse Winnox WX Series Installation Manual page 21

Hide thumbs Also See for Winnox WX Series:
Table of Contents

Advertisement

tep 5:
et high fire gas
Tap
1
"B"
Tap
"C"
2
Figure 4.9 High fire gas adjustment
et high fire gas procedure
1.
et manual gas BV to 75% open.
ote:
To adjust manual BV:
.
b.
c.
2.
position.
Measure ai r l o adi n g l i n e pressure from Tap “C” to
To
3.
Chamber
chamber.
Refer to “Ai r
4.
Sheet and determine the desired input for measured air
P.
Measure gas flow and input using customer supplied
5.
measuring device.
Adjust high fire gas flow using manual butterfly valve
6.
Refer to step 1 for adjustment procedure) to match
the desired input determined in step 4.
7.
Measure gas pressure at the burner inlet
the pressure is within the range specified on the Data
Sheet.
8
. If required gas flow cannot be achieved, refer to
Chapter 5, Maintenance and T roubleshooting for
guidance.
clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05
Loosen set screw.
Turn outer dial.
Tighten set screw.
ith burner lit, drive control motor to high fire
P vs. Input” graph on appropri a te Data
and verify
1

Advertisement

Table of Contents
loading