Eclipse Winnox WX Series Installation Manual page 11

Hide thumbs Also See for Winnox WX Series:
Table of Contents

Advertisement

E
NSTALLAT ON
ECKLIST
RNER
Minimum 1/4" (6mm)
space per side
Combustor
Chamber wall
"C"
ir Supply
rovide an opening in the burner room of at least one square
inch per 3000 BTU/hr (5 cm per 1 kW) to supply the burner
intake with fresh, outdoor, combustion air.
If there are corrosive fumes or materials in the surrounding air,
find an uncontaminated source to supply air to the burner.
xhaust
o not allow exhaust gases to accumulate in the work area.
Provide a means for exhausting these gases from the building.
ccess
nstall the burners so they may be easily accessed for
inspection and maintenance.
nvironment
e sure the burner operating environment matches the original
operating specifications. Check the following items:
 voltage, frequency, and stability of electrical power
 fuel type and fuel supply pressure
 adequate fresh, clean, combustion air
 humidity, altitude, and temperature of the supply air
 presence of damaging corrosive gases in the air
 prevent direct exposure to water.
hamber Opening
rovide an opening in the chamber wall at least ½” (12mm)
larger in diameter than the outside diameter of the combustor
(1/4” - 6mm per side).
rovide an accessible pressure tap on the chamber wall to
measure the pressure inside the firing chamber. The pressure
tap should be located near the burner.
ounting Pattern
ttach eight mounting bolts to the chamber wall. Position these
bolts to match the clearance holes (C) on the burner
mounting flange. Refer to the appropriate Winnox data sheet.
clipse Winnox WX Series v1, Installation Guide No. 111, 8/26/05