(4) Setup for Display
Select "9. Screen Display" from the main menu, then switch from "Upper Left Side
Display" to "Lower Right Side Display" using the sub-menu "1. Water Temperature
Value Display Position" (it is set to OFF when the system is delivered to you).
For the operation, see page 20 in the Instruction Manual.
CHG-97 External View
External view
Connector 8P
Nishin parts NS-1008
( unit : mm )
2-inch screw
Water turbine (boat
speed sensor)
Figure 2.2 Outline Dimensions CHG-97
24
Specification:
1. Speed sensor
22000 pulse/N.M (equivalent
to 1.8 km)
2. Temperature sensor
10 KΩ/25C
3. Cable length
10 meters
Cable
Sensor
body
Sensor body
mounting nut
Housing
mounting nut
Housing