Plessey Redundancy
If you are encountering errors when reading Plessey bar codes, you may want to adjust the redundancy count. Redun-
dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.
Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan
the Plessey Redundancy bar code below, then scan a redundancy count between 0 and 10 on the
Programming Chart
inside the back cover of this manual. Then scan the
Save
bar code. Default = 0.
Plessey Redundancy

Plessey Message Length

Scan the bar codes below to change the message length. Refer to
Message Length Description
(page 7-1) for additional
information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.
Minimum Message Length
Maximum Message Length

GS1 DataBar Omnidirectional

< Default All GS1 DataBar Omnidirectional Settings >
GS1 DataBar Omnidirectional On/Off
* On
Off
GS1 DataBar Omnidirectional Redundancy
If you are encountering errors when reading GS1 DataBar Omnidirectional bar codes, you may want to adjust the redun-
dancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the
redundancy, scan the GS1 DataBar Omnidirectional Redundancy bar code below, then scan a redundancy count
between 0 and 10 on the
Programming Chart
inside the back cover of this manual. Then scan the
Save
bar code. Default
7 - 46