Honeywell Voyager 1200g User Manual page 91

Single-line laser bar code scanner
Hide thumbs Also See for Voyager 1200g:
Table of Contents

Advertisement

SEQBLKsequence editor start command
62
code identifier for Code 39
9999
code length that must match for Code 39, 9999 = all lengths
41
start character match for Code 39, 41h = "A"
FF
termination string for first code
6A
code identifier for Code 128
9999
code length that must match for Code 128, 9999 = all lengths
42
start character match for Code 128, 42h = "B"
FF
termination string for second code
69
code identifier for Code 93
9999
code length that must match for Code 93, 9999 = all lengths
43
start character match for Code 93, 43h = "C"
FF
termination string for third code
To program the previous example using specific lengths, you would have to count any programmed prefixes, suffixes, or for-
matted characters as part of the length. If you use the example on
lengths, you would use the following command line:
SEQBLK62001241FF6A001342FF69001243FF
The breakdown of the command line follows:
SEQBLKsequence editor start command
62
code identifier for Code 39
0012
A - Code 39 sample length (11) plus CR suffix (1) = 12
41
start character match for Code 39, 41h = "A"
FF
termination string for first code
6A
code identifier for Code 128
0013
B - Code 128 sample length (12) plus CR suffix (1) = 13
42
start character match for Code 128, 42h = "B"
FF
termination string for second code
69
code identifier for Code 93
0012
C - Code 93 sample length (11) plus CR suffix (1) = 12
43
start character match for Code 93, 43h = "C"
FF
termination string for third code
page
4-14, but assume a <CR> suffix and specific code
4 - 15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Voyager 1202g

Table of Contents