NEC Electra Elite IPK II Installation And Maintenance Manual page 44

H.323 trunk
Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Document Revision 1
___________________________________________________________________________________
Q u e s t i o n :
The Electra Elite system does not recognize the IAD(8)-U( ) ETU and displays
UNUSED for any attempt to seize the assigned trunk.
A n s w e r :
Make sure the Electra Elite system is programmed for the same card type using
Memory Block 7-1 (Card interface Slot Assignment) as the operating mode of the
IAD(8)-U( ) ETU. For example, if the IAD(8)-U( ) ETU is in slot 3 of cabinet 1 and
operating as a COID(8)-U10 ETU, the Electra Elite IPK II system must be
programmed, using a PC or handset, for a COID(8)-U10 ETU in slot 3 of cabinet 1.
Q u e s t i o n :
What IP Ports are needed for H.323 Trunk operation?
A n s w e r :
For the H.323 Trunk card and the H.323 Protocol the following ports are necessary:
S
3
R
ECTION
ETURNING THE
C
ONFIGURATION
To return the IAD(8)-U( ) ETU to the default configuration:
1.
2.
3.
4.
5.
___________________________________________________________________________________
B - 2
Application
H.323 Protocol
H.323 Trunk Card IAD(8)-U( ) ETU
IAD(8)-U( ) ETU (H.323 T
Remove the IAD(8)-U( ) ETU.
Set DIP switches S2(1) ~ S2(8) in the ON position (factory default).
Replace the IAD(8)-U( ) ETU in the KSU.
When the bootup process is completed, the IAD(8)-U( ) ETU is restored to the
factory default package.
The IAD(8)-U( ) ETU Default IP Address is: 192.168.1.100. The subnet mask is
255.255.255.0.
Port Numbers
1720
49150
)
RUNK
TO
H.323 Trunk
Comments
TCP/UDP
Starting RTP Port
D
EFAULT
Troubleshooting