4.7 Emergency stop from LOP

CAUTION
An emergency stop causes extreme stress to the engine.
Risk of overheating, damage to components!
• Initiate emergency stop only in emergency situations.
Emergency stop from LOP
Item
LOP
LOP
After emergency stop from LOP
Item
LOP
LOP
Engine
Task
Open cap of EMERGENCY STOP button (→ Page 110).
Press EMERGENCY STOP button.
• Engine is stopped by switching off power supply to ECU;
• Engine control is deactivated;
• Engines with emergency air-shut-off flaps: Flaps close;
• EMERGENCY STOP button flashes.signalization by horn, flash lamp
etc. is released.
Task
Press ALARM ACKNOWLEDGE button (→ Page 110).
• Audible and visual signalization stops.
Press ALARM ACKNOWLEDGE button again.
• Power supply to ECU is provided;
• Alarm is acknowledged.
Engines with emergency air-shut-off flaps: Flaps open.
• Engine is ready for operation.