Raw-water circuit (open circuit)
Number of cylinders
Raw water pump: Inlet pressure, min.
Raw water pump: inlet pressure, max.
Pressure loss in off-engine raw-water system, max.
Lube oil system
Number of cylinders
Lube-oil operating temperature before engine, from
Lube-oil operating temperature before engine, to
Lube-oil operating pressure before engine, from
Lube-oil operating pressure before engine, to
Lube oil operating pressure (low idle) (meas. point: before engine)
Fuel system
Number of cylinders
Fuel pressure at engine inlet connection, min. (when engine is starting)
Fuel pressure at engine inlet connection, min. (when engine is running)
Fuel pressure at engine inlet connection, max. (when engine is starting)
Fuel supply flow, max.
General operating data
Number of cylinders
Firing speed, from
Firing speed, to
Starter (electric)
Number of cylinders
Rated starter voltage (standard rating)
Starter (with air/hydraulic starter motor)
Number of cylinders
Starting-air pressure before starter motor, min.
Starting-air pressure before starter motor, max.
Capacities
Number of cylinders
Engine coolant, engine side (with cooling system)
Engine oil capacity, initial filling (standard oil system) (Option: max. operat‐
ing inclinations)
Oil change quantity, max. (standard oil system) (Option: max. operating in‐
clinations)
L
L
L
R
R
R
R
R
L
L
L
A
R
R
R
R
R
R
R
R
MS150031/05E 2013-01 | Technical Data | 61
8
bar
-0.2
bar
0.5
bar
1.0
8
°C
70
°C
75
bar
5.6
bar
6.1
bar
2.0
8
bar
-0.3
bar
-0.3
bar
0.5
liters/min
2.05
8
rpm
100
rpm
120
8
V=
24
8
bar
18*
bar
30
8
Liters
70
Liters
65
Liters
60