RAW WATER CIRCUIT (open circuit)
Number of cylinders
Raw water pump: Inlet pressure, min.
Raw water pump: Inlet pressure, max.
Pressure loss in external raw water system, max.
LUBE OIL SYSTEM
Number of cylinders
Lube-oil operating temperature before engine, from
Lube oil operating temperature before engine, to
Lube oil operating pressure before engine, from
Lube oil operating pressure before engine, to
Lube oil operating pressure (low idle) (meas. point: before engine)
FUEL SYSTEM
Number of cylinders
Fuel pressure at engine supply connection, min. (when engine is starting)
Fuel pressure at supply connection to engine, min. (when engine is run‐
ning)
Fuel pressure at engine supply connection, max. (when engine is starting)
Fuel supply flow, max.
GENERAL OPERATING DATA
Number of cylinders
Firing speed, from
Firing speed, to
STARTING (electric)
Number of cylinders
Starter, rated voltage (standard design)
STARTING SYSTEM (with air/hydraulic starter motor)
Number of cylinders
Starting air pressure before starter motor, min.
Starting air pressure before starter motor, max.
CAPACITIES
Number of cylinders
Engine coolant, engine-side (with cooler)
Engine oil at initial filling (standard oil system) (Option: max. operating incli‐
nations)
Oil change quantity, max. (standard oil system) (Option: max. operating in‐
clinations)
L
L
L
R
R
R
R
R
L
L
L
R
R
R
R
R
R
R
R
R
MS150031/05E 2013-01 | Technical Data | 49
8
bar
-0.2
bar
+0.5
bar
1.0
8
°C
75
°C
80
bar
5.6
bar
6.1
bar
2.0
8
bar
-0.3
bar
-0.3
bar
+0.5
liter/min
1.6
8
rpm
100
rpm
120
8
V=
24
8
bar
18*
bar
30
8
liter
70*
liter
65
liter
60