11. Soft Switch List
MODE
Bit:
198
1
Bit
Feature
TX forwarding to adminis-
7
trator <*>
TX forwarding of scanner
6
function to administrator
<*>
5
Result report TX forward-
ing to administrator
4
NOTE
1
• (*1): Bit 7 of mode 198 is enabled only when "1 (forwarded)" is specified.
MODE
1
Bit:
202
Bit
2
TCF continuous sending
1
PIX continuous sending
MODE
212 (PSTN1)
232 (PSTN2)
Bit
Feature
7
Select DP make rate.
6
102
Factory setting bit
7 6 5 4
3 2 1 0
1 1 0 1
0 0 0 0
Logic
0
Not for-
warded
Not for-
warded
Bit 5-4:
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 0
0 0 0 0
Feature
0
No
No
Bit:
7 6 5 4
0 0 0 0
Logic
0
Bit 7-6:
Field Service Ver. 2.0 Apr. 2006
HEX:D0
1
For-
Specifies whether a received document
warded
is forwarded to a destination specified by
the administrator.
For-
Specifies whether to enable TX For-
warded
warding when scanning. (*1)
00
Not output
01
Output for
incomplete TX
10
Always output
11
Not available
HEX: 00
Logic
1
Yes
By setting 1, TCF signal remains in
being sent. To reset the mode, turn
ON/OFF the power.
Yes
By setting 1, PIX signal remains in
being sent. To reset the mode, turn
ON/OFF the power.
Factory setting bit
3 2 1 0
HEX:40 (For U.S.)
0 0 0 0
HEX:00 (For Europe)
1
00
33 %
01
40 %
Others
Not available
Description
Specifies the print
conditions of trans-
mission reports for TX
Forwarding. (*1)
Description
Description
Specify the DP signal
make ratio.

Hide quick links: