11. Soft Switch List
MODE
098 (PSTN1)
128 (PSTN2)
Bit
Feature
7
Select starting time of
sending CM signal.
6
3
2
1
Select EQM threshold
value.
0
98
Factory setting bit
Bit:
7 6 5 4
0 1 0 0
Logic
0
Bit 3-6:
00
01
10
11
Bit 3-0:
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
Others
Field Service Ver. 2.0 Apr. 2006
3 2 1 0
HEX:46
0 1 1 0
Description
1
0 sec
1 sec
Use this soft switch for
error in V8 sequence.
2 sec
3 sec
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
Not available