Field Service Ver. 1.0 Aug. 2005
2.3.2

Switch Back Unit

A. Fan Motor Cover/Right Cover
1. Remove two screws [1] and Fan Motor Cover [2].
2. Remove two screws [3] and Right Cover [4].
2.4

Cleaning procedure

NOTE
• The alcohol described in the cleaning procedure represents the isopropyl alcohol.
2.4.1
Cleaning of the Duplex Unit Transport Roller/Roll 1 and 2
2.4.2
Cleaning of the Duplex Unit Transport Roller/Roll 3
[2]
[1]
[1]
[1]
4040F2C502DA
4040F2C503DA
[3]
[2]
1. Open the Duplex Unit Door.
2. Using a soft cloth dampened with
alcohol, wipe the Duplex Unit Trans-
port Roller/Roll 1 and 2 [1] clean of
dirt.
1. Remove the Duplex Unit.
2. Using a soft cloth dampened with
alcohol, wipe the Duplex Unit Trans-
port Roller/Roll 3 [2] clean of dirt.
2. Other
[4]
4526F2C500DA
5