DLP Projector—User's Manual
RS-232C Protocol
RS232 Setting
Baud rate:
Parity check:
Data bit:
Stop bit:
Flow Control
Control Command Structure
HEX
ASCII
Operation Command
Note:
XX=00-98, projector's ID, XX=99 is for all projectors
Return Result P=Pass / F=Fail
n: 0:Disable/1: Enable/Vaule(0~9999)
ASCII
VXXS0001
56h Xh Xh 53h 30h 30h 30h 31h 0Dh
VXXS0002
56h Xh Xh 53h 30h 30h 30h 32h 0Dh
VXXS0003
56h Xh Xh 53h 30h 30h 30h 33h 0Dh
VXXG0004
56h Xh Xh 47h 30h 30h 30h 34h 0Dh
VXXS0006
56h Xh Xh 53h 30h 30h 30h 36h 0Dh
VXXG0007
56h Xh Xh 47h 30h 30h 30h 37h 0Dh
VXXG0008
56h Xh Xh 47h 30h 30h 30h 38h 0Dh
9600
None
8
1
None
Header code
Command code
Command
'V'
Command
Command Group 00
HEX
— 72 —
Data code
Data
Data
Function
Description
Power On
Power Off
Resync
Get Lamp Hours
System Reset
0:Reset
1:Standby
Get System Status
2:Operation
3:Cooling
Get F/W Version
A
I
PPENDIX
End code
0Dh
CR
Return Result
P/F
P/F
P/F
Pn/F
P/F
Pn/F
Pn/F