Advanced Entry Calibration - Datamax M-Class Operator's Manual

Printers
Table of Contents

Advertisement

5.4.3

Advanced Entry Calibration

Advanced Entry Calibration is the alternate method for special-case media types. The procedure has two parts:
1) You must list the sensor readings for the label and TOF values using different algorithms.
2) From your list the best algorithm is chosen, new readings taken and those values entered.
Advanced Entry Calibration will override all previous calibration settings; this method should be used only when Standard
Calibration has failed.
To perform an Advanced Entry Calibration:
Step
Operator Action
1
(Media should be loaded and the
appropriate Sensor Type selected.)
Turn 'On' the printer.
Press the
MENU
2
Raise the printhead assembly.
3
Press the
Key to enter the
Media Settings menu.
4
Press the
Key and scroll
FWD
to 'Sensor Calibration'.
5
Press the
Key.
72
Displayed Message
!
!!
VODBMJCSBUFE!
!
!
Key.
NFOV!NPEF!
NFEJB!TFUUJOHT!
!
!
!
NFEJB!TFUUJOHT!
NFEJB!UZQF!
!
!
!
NFEJB!TFUUJOHT!
TFOTPS!DBMJCSBUJPO!
!
!
TFOTPS!DBMJCSBUJPO!
QFSGPSN!DBMJCSBUJPO!
!
Wait until the printer initializes (about six seconds).
You are entering Menu Mode.
!!
See Section 5.1.2 for menu layout.
!!
Press the
!!
You are entering the calibration submenu.
Comment
Key to abort this procedure.
M-Class