4-4
Specs and Accessories
OHMS
ENHANCED ACCURACY
RANGE
Transfer
5
20
2.5 + 3
200
2.5 + 2
2 k Ω
1.3 + 0.2
20 k Ω
1.3 + 0.2
200 k Ω
2.5 + 0.4
2 M Ω
5
+ 0.2
20 M Ω
2
15
+ 0.1
200 M Ω
2
50
+ 0.5
1 G Ω
2
250
+ 2.5
1. Specifications are for 10 power line cycles, 10-reading repeat digital filter, synchronous autozero, autorange off, 4-wire mode, offset com-
pensation on (for 20 Ω to 20k Ω ranges), except as noted.
2. For 2-wire mode.
3. For T
±1°C, following 4-hour warm-up. T
CAL
4. For T
±5°C, following 4-hour warm-up.
CAL
5. Specifications apply for 20-reading repeat digital filter, T
10% of the initial measurement value and within 10 minutes of the initial measurement time.
RESISTANCE UNCERTAINTY = ± [ (ppm of reading) × (measured value) + (ppm of range) × (range used) ] / 1,000,000.
% ACCURACY = (ppm accuracy) / 10,000.
1PPM OF RANGE = 20 counts for ranges up to 200M Ω and 10 counts on 1G Ω range at 7
KEITHLEY FACTORY CALIBRATION UNCERTAINTY
RANGE
ppm of reading
20
200
2 k Ω
20 k Ω
200 k Ω
2 M Ω
20 M Ω
200 M Ω
1 G Ω
DC AMPS
DCI INPUT CHARACTERISTICS AND ACCURACY
FULL
RANGE
SCALE
200 µA
210.00000
2 mA
2.1000000
20 mA
21.000000
200 mA
210.00000
2
A
2.1000000
1. Specifications are for 1 power line cycle, autozero on, 10-reading repeat digital filter.
2. For T
± 1°C, following 55-minute warm-up. T
CAL
3. For T
± 5°C, following 55-minute warm-up.
CAL
4. Actual maximum burden voltage = (maximum burden voltage) × (I
- 10PLC, Offset comp. on, DFILT 10
1
RELATIVE ACCURACY
± (ppm of reading + ppm of range)
24 Hours
3
90 Days
5
+ 4.5
15 + 6
5
+ 3
15 + 4
2.5 + 0.3
7 + 0.4
2.5 + 0.3
7 + 0.4
4.5 + 0.5
17 + 0.8
10
+ 0.3
38 + 0.5
50
+ 0.2
175 + 0.6
150
+ 1
500 + 3
750
+ 5
2000 + 15
is ambient temperature at calibration (23°C at the factory).
CAL
REF
29.5
Factory calibration uncertainty represents traceability to NIST. This uncertainty is added to
relative accuracy specifications to obtain absolute accuracies. The 20 Ω - 2M Ω range un-
7.7
certainties are equal to the uncertainty of the respective calibration sources. The 20M Ω ,
6.4
200M Ω , and 1G Ω range uncertainties are equal to the uncertainty of the 2M Ω calibration
7.8
7.3
source.
14.9
14.9
14.9
14.9
MAXIMUM
RESO-
BURDEN
4
LUTION
VOLTAGE
24 Hours
10 pA
0.25 V
50 + 6
100 pA
0.3 V
50 + 5
1 nA
0.35 V
50 + 5
10 nA
0.35 V
75 + 5
100 nA
1.1 V
350 + 5
is ambient temperature at calibration (23°C at the factory).
CAL
4
1 Year
4
2 Years
17 + 6
20 + 6
17 + 4
20 + 4
9 + 0.4
11 + 0.4
9 + 0.4
11 + 0.4
21 + 0.9
25 + 1
50 + 0.5
62 + 0.5
250 + 0.6
300 + 0.6
550 + 3
600 + 3
2050 + 15
2100 + 15
± 0.5°C (T
is the initial ambient temperature), and for measurements within
REF
digits.
RELATIVE ACCURACY
±(ppm of reading + ppm of range)
2
3
90 Days
1 Year
275 + 25
350 + 25
275 + 20
350 + 20
275 + 20
350 + 20
300 + 20
375 + 20
600 + 20
750 + 20
/I
MEASURED
FULL SCALE
TEMPERATURE
COEFFICIENT
± (ppm of reading +
ppm of range) / °C
4
Outside T
±5°C
CAL
2.5 + 0.7
2.5 + 0.5
0.8 + 0.05
0.8 + 0.05
3
+ 0.18
6
+ 0.1
20
+ 0.1
80
+ 0.5
400
+ 2.5
TEMPERATURE
COEFFICIENT
1
±(ppm of reading +
ppm of range)/°C
3
3
2 Years
Outside T
500 + 25
50 + 5
500 + 20
50 + 5
500 + 20
50 + 5
525 + 20
50 + 5
1000 + 20
50 + 5
).
1
±5°C
CAL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents